Dealing with comfort disruption
Use the following list to find and remedy any heating or
hot water problems.
Action
Cause
Symptom
Check and replace blown fuses.
Circuit or main miniature circuit breaker
(MCB) tripped.
Low hot water temperature or a lack of hot
water.
Check and replace any blown circuit and
main fuses.
Heat pump and immersion heater do not
heat.
Reset the earth circuit-breaker, if the earth
circuit-breaker trips repeatedly, call an
electrician.
Possible earth circuit-breaker tripped.
Set the switch to 1.
Switch (SF1) set to mode 0.
Wait a few hours and check if the hot water
temperature rises.
Large hot water demand.
Adjust the start temperature setting in
menu 1.2.
Too low start temperature setting on the
control system.
Reset the earth circuit-breaker, if the earth
circuit-breaker trips repeatedly, call an
electrician.
Possible earth circuit-breaker tripped.
Low room temperature.
Check and replace any blown circuit and
main fuses.
Heat pump and immersion heater do not
heat.
Adjust the setting.
Incorrect setting of "Curve slope", "Heating
curve, offset" and/or "Cooling curve, off-
set".
Check and replace blown fuses.
Circuit or main miniature circuit breaker
(MCB) tripped.
Change operating mode to ”Auto” or "Au-
toK".
Heat pump in incorrect operating mode
”Hot water” or "Cooling".
Switch off one/several of the power con-
sumers.
The current limiter has restricted the cur-
rent because many power consumers are
being used in the property.
Adjust the setting.
Incorrect setting of "Curve slope", "Heating
curve, offset" and/or "Cooling curve, off-
set".
High room temperature.
Change operating mode to ”AutoK”.
Heat pump in incorrect operating mode.
Adjust the settings. Check menu 2.2.1, 2.2.2
and 8.2.4.
Incorrect settings for cooling.
Wait 30 minutes and check if the com-
pressor starts.
Minimum time between compressor starts,
alternatively time after power switch on
not achieved.
The compressor does not start.
See section ”Alarms”.
Alarm tripped.
Activate operating mode ”Only additional
heat”.
Alarm cannot be reset.
Check and replace any blown circuit and
main fuses.
Display not lit.
Check that the circuit breaker to the indoor
unit is not off.
Check that the switch (SF1) is in normal
position (1).
NIBE™ SPLIT
14
For Home Owners
Dealing with comfort disruption
Содержание AMS 10-16
Страница 2: ...HE 30 LEK LEK LEK LEK LEK HEV 300 LEK HEV 500 LEK LEK AMS 10 16 LEK HBS 16 ...
Страница 70: ...Electrical circuit diagram HBS 16 NIBE SPLIT 68 Miscellaneous Electrical circuit diagram ...
Страница 71: ...69 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 72: ...NIBE SPLIT 70 Miscellaneous Electrical circuit diagram ...
Страница 73: ...71 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 74: ...NIBE SPLIT 72 Miscellaneous Electrical circuit diagram ...
Страница 75: ...73 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 76: ...AMS 10 16 NIBE SPLIT 74 Miscellaneous Electrical circuit diagram ...
Страница 86: ...Dimensions Indoor unit HBS 16 600 1040 1140 375 Under Front Right NIBE SPLIT 84 Miscellaneous Dimensions ...
Страница 87: ...Hot water tank HE 30 178 98 418 360 590 5LJKW URQW ERYH 85 NIBE SPLIT Miscellaneous Dimensions ...
Страница 100: ...NIBE SPLIT 98 ...
Страница 101: ...99 NIBE SPLIT ...
Страница 102: ...NIBE SPLIT 100 ...
Страница 103: ......