Emptying the coil in the water heater
The water heater is of the coil type and the pressure in the
domestic coil can be released by closing the incoming
water and opening the hot water tap. However, some
water may remain in the domestic coil. Drain by removing
the XL3 cold water connection on the heater.
Emptying the vessel
Contact your installer if the vessel in HE 30, HEV 300, HEV
500 needs emptying.
Maintenance of AMS 10
AMS 10 is equipped with control and monitoring equip-
ment, however some exterior maintenance is still neces-
sary.
Make regular checks throughout the year that the inlet
grille is not clogged by leaves, snow or anything else.
During the cold months of the year, check to make sure
that there isn't a build up of ice or frost under AMS 10.
Strong wind combined with heavy snowfall can block the
intake and exhaust air grilles. Make sure that there is no
snow on the grilles.
Also check that the condensation water drain under AMS
10 is not blocked.
If necessary the outer casing can be cleaned using a damp
cloth. Care must be exercised so that the heat pump is not
scratched when cleaning. Avoid spraying water into the
grilles or the sides so that water penetrates into AMS 10.
Prevent AMS 10 coming into contact with alkaline cleaning
agents.
!
WARNING!
Rotating fan in AMS 10.
Saving tips
Your NIBE SPLIT installation produces heat and hot water
according to your needs. It also attempts to carry out all
requirements with all available ”aids” from the control
settings made.
The indoor temperature is naturally affected by the energy
consumption. Therefore, take care not to set a temperature
higher than necessary.
Other known factors that affect the energy consumption
are, for example, hot water consumption and the insula-
tion level of the house, as well as the level of comfort you
require.
Also remember:
႑
Open the thermostat valves completely (except in the
rooms that are to be kept cooler for various reasons, e.g.
bedrooms).
Thermostat valves in the radiators and floor loops can
negatively affect the energy consumption. They slow the
flow in the climate system, which the heat pump wants to
compensate with increased temperatures. It then works
harder and consumes more electrical energy.
13
NIBE™ SPLIT
For Home Owners
Maintenance
Содержание AMS 10-16
Страница 2: ...HE 30 LEK LEK LEK LEK LEK HEV 300 LEK HEV 500 LEK LEK AMS 10 16 LEK HBS 16 ...
Страница 70: ...Electrical circuit diagram HBS 16 NIBE SPLIT 68 Miscellaneous Electrical circuit diagram ...
Страница 71: ...69 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 72: ...NIBE SPLIT 70 Miscellaneous Electrical circuit diagram ...
Страница 73: ...71 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 74: ...NIBE SPLIT 72 Miscellaneous Electrical circuit diagram ...
Страница 75: ...73 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Страница 76: ...AMS 10 16 NIBE SPLIT 74 Miscellaneous Electrical circuit diagram ...
Страница 86: ...Dimensions Indoor unit HBS 16 600 1040 1140 375 Under Front Right NIBE SPLIT 84 Miscellaneous Dimensions ...
Страница 87: ...Hot water tank HE 30 178 98 418 360 590 5LJKW URQW ERYH 85 NIBE SPLIT Miscellaneous Dimensions ...
Страница 100: ...NIBE SPLIT 98 ...
Страница 101: ...99 NIBE SPLIT ...
Страница 102: ...NIBE SPLIT 100 ...
Страница 103: ......