4.2 Operation example in constant current mode (total)
HVA4321
4-17
c)
Output mode settings
Set the output mode switch to CC. Set the DC BIAS to CC.
Figure4-21. Output mode settings
d)
Remote/local settings
To operate this unit from the panel, set the ON/OFF CONTROL switch to LOCAL.
Refer to "4.6 Remote control operation" for remote control operation.
Figure4-22. Local settings
OVERLOAD
CV
1kV/1V
CC
1mA/ 1V
DC BI AS
CV
CC
CV
1kV/ 1V
CC
1mA/1V
CURRENT
SELECT
LOAD
TOTAL
ON/ OFF
CONTROL
REMOTE
LOCAL
ON
OFF
EXT DC BI AS
OUTPUT
TTL(Lo: ON)
Zout 10k
Ω
SI GNAL ON/ OFF STATUS
OUTPUT
MONI TOR
1V/ 1kV
Zout 50
Ω
VOLTAGE
CURRENT
±
10V MAX
Zi n 10k
Ω
1V/1mA
Zout 50
Ω