4.3 Operation example in constant current mode (load)
HVA4321
4-28
Figure4-34. Load mode
lamp
: Output current of amplifier
lint
: Leak current with internal capacity
lout
: Output current
lstr
: Leak current with wire capacity
lload
: Load current
lac, ldc
: DC and AC of detected current
Not all current lout from the output terminal is supplied to load. There is leak of lstr with wire capacity.
Actual current to load is lload = lout - lstr.
In load mode, lload and lstr are returned through different routes and only lload is detected to control
output current.
Therefore, Set current = lload
lout = lload + lstr
Current lout from the output terminal cannot exceed the maximum current of this unit.
In load mode, load current is directly detected. Only load current can be monitored with the current
monitor.
内部容 量
出力端子
配線 の容量
負荷 抵抗
電流検出 抵抗
電流 検出抵抗
(トータ ル用)
(ロード 用)
電流モ ニタ
OUTPUT Hi
OUTPUT Lo
TOTAL
LOAD
I out
Ii nt
Istr
Il oad
I amp
I dc+I ac
電圧 モニタ
Output terminal
Load
resistance
Wire capacity
Internal capacity
Current detection
resistance
(for total)
Current monitor
Voltage
monitor
Current detection resistance
(for load)
!
CAUTION
Содержание HVA4321
Страница 1: ...INSTRUCTION MANUAL NF Corporation HVA4321 10kV AC DC AMPLIFIER HVA4321 10kV AC DC AMPLIFIER...
Страница 2: ......
Страница 4: ......
Страница 8: ...HVA4321 iv...
Страница 16: ...Figures HVA4321 xii...
Страница 18: ...HVA4321 1 2...
Страница 24: ......
Страница 30: ...2 3 Grounding and power supply connection HVA4321 2 6...
Страница 32: ......
Страница 50: ......
Страница 52: ......
Страница 54: ......
Страница 56: ......
Страница 116: ......
Страница 127: ...6 Troubleshooting 6 1 When suspecting a fault 6 1...
Страница 128: ......
Страница 132: ......
Страница 138: ......
Страница 148: ......
Страница 150: ......
Страница 151: ......