8.9 Setting Memory
BP4620
8-9
8.9 Setting
Memory
Settings are backed up and the settings that were applied the previous time the BP4620 was powered
off can be restored the next time is powered on. However, the selected response characteristics are
not saved. Moreover, among the various settings, the basic settings (operation mode, DC,
superimposed AC, output limiters) can be saved to store/recall memories No. 1 to No. 30, and the
saved settings can be called and used.
The store/recall memory call operation is possible only when the output is off.
8.10 Protective Functions
Output overload:
If output voltage over, output current over, or internal power loss
over is detected, overload is displayed on the panel screen, and the
output voltage or current is reduced. If the overload status continues
10 or more seconds, the output is switched off.
Power supply anomaly:
Upon anomaly detection, the output and power are both switched off.
Internal overheating:
Upon anomaly detection, the output and power are both switched off.
Operation panel anomaly:
Upon detection of an operation panel anomaly such as the operation
panel being disconnected from the main unit, the output and power
are both switched off.
8.11 General
LCD settings
Contrast:
Adjustable
Display color:
Blue or white
Beep:
On or off
If on, a beep is emitted during key operation and malfunction. A
warning sound is emitted upon overload detection, regardless of this
setting.
Keylock:
On or off
In the on status, only keylock off operation and output off operation
are possible.
Output setting at power-on:
On or off
When on, the output is automatically switched on at power-on.
Response characteristics setting at power-on:
On or off
When on, the response characteristics are automatically set to
adjusted characteristics at power-on.
Reset function:
Returns the basic settings to the factory default settings.
Self-diagnosis function:
Performs check of each memory at power-on.
Содержание BP4620
Страница 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Страница 3: ......
Страница 15: ......
Страница 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Страница 21: ......
Страница 39: ......
Страница 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Страница 171: ......
Страница 187: ......
Страница 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Страница 211: ......
Страница 213: ......