5.3 Explanation of Each Program Message
BP4620
5-11
WAVE/WAVE?
Description:
Selects the superimposed current waveform.
Parameter: 0:
SIN
(sine
wave)
1: SQU (square wave)
2 to 17: ARB1 to ARB16 (arbitrary waveform)
Setting example:
Setting the waveform to be output to sine wave
WAVE
0
Caution:
Setting cannot be performed when output is on.
5.3.2 Limiter
LMCM/LMCM?
Description: Sets
the
current limiter.
Parameter: Current
[A]
52.0 A to
2.0 A
Setting example:
Setting the – current limiter to
15 A
LMCM
15
Caution:
Settable in units of 0.1 A
LMCP/LMCP?
Description:
Sets the + current limiter.
Parameter: Current
[A]
2.0 A to 52.0 A
Setting example:
Setting the + current limiter to 15 A
LMCP 15
Caution:
Settable in units of 0.1 A
LMVM/LMVM?
Description:
Sets the – voltage limiter.
Parameter: Voltage
[V]
117.0 V to
7.0 V
Setting example:
Setting the – voltage limiter to –100 V
LMVM
100
Caution:
Settable in units of 0.1 A
LMVP/LMVP?
Description:
Sets the + voltage limiter.
Parameter: Voltage
[V]
7.0 V to 117.0 V
Setting example:
Setting the + voltage limiter to 100 V
LMVP
100
Caution:
Settable in units of 0.1 V
Содержание BP4620
Страница 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Страница 3: ......
Страница 15: ......
Страница 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Страница 21: ......
Страница 39: ......
Страница 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Страница 171: ......
Страница 187: ......
Страница 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Страница 211: ......
Страница 213: ......