8.1 Specification Conditions
BP4610
8-1
8.1 Specification
Conditions
Unless otherwise specified, the following conditions apply.
Power supply input:
100 V AC
±
10 V, 50 Hz
Output frequency:
1 kHz
Signal:
External input signal
Output waveform:
Sine wave (DC = 0 V)
Output voltage, current:
±
60 V,
±
10 A
Load: 6
Ω
resistance
Response characteristics:
Fixed characteristics
Output voltage limiter setting:
±
62 V
Output current limiter setting:
±
26 A
In this chapter, the terms “fixed characteristics” and “adjusted characteristics” have the following
meanings.
Fixed characteristics
These characteristics are fixed when the BP4610 is shipped and cannot be changed by the user.
They are set with the aim to achieve both wide frequency band characteristics and load
stability.
Adjusted characteristics
These characteristics are adjusted by the user for the CV or CC mode using the response
calibration function, so as to achieve the fastest possible step response waveform rise time
and fall time, as well as overshoot, undershoot, and sag that fall within
±
5% of the P-P
amplitude.
Содержание BP4610
Страница 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual nbn Austria GmbH...
Страница 2: ......
Страница 3: ...DA00010493 001 BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual...
Страница 4: ......
Страница 16: ......
Страница 17: ...BP4610 1 OVERVIEW 1 1 General 1 1 1 2 Features 1 1 1 3 Principle of Operation 1 3...
Страница 18: ......
Страница 24: ......
Страница 38: ......
Страница 40: ......
Страница 48: ......
Страница 134: ......
Страница 162: ......
Страница 164: ......
Страница 167: ...6 1 Error Messages BP4610 6 3 Figure 6 1 Protective Function Related Error Display Examples...
Страница 174: ......
Страница 190: ......
Страница 207: ...BP4610 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 1...
Страница 208: ......
Страница 212: ......
Страница 214: ......
Страница 216: ......
Страница 217: ......