Installation instructions for the BANC D.sign above water automatic slatted safety cover - 4/24
4
1. Preparing the pool
1.1 Electric connections and cable passages
1.1.1
Electric box power supply
Fig. 1
Prepare a 230 V power supply using an R2V
3G2.5 mm² (or Ro2V 3G2.5 mm²) cable for the
electric box, which must be installed outside volumes
⓪, ① and ②, and in a dry place (technical room).
1.1.2
Electrical protection
This power supply must be protected by a circuit
breaker or a 10 A fuse and a 30 mA ground fault
circuit breaker.
1.1.3
Sheaths
Prepare a connection protected by a sheath for the
power supply between the box and the roller using
2 x 4 mm² size wire if the cable is less than 15 m long
and using 2 x 6 mm² size wire if the cable is between
15 m and 30 m long.
Prepare a connection protected by a sheath to
couple the treatment control box between the
control box and the roller using 2 x 1.5 mm² wire.
1.1.4
Cable passage
Separate cables transporting different voltages
(24 V and 220 V) and pass them freely in different
protective sheaths and connect removing all risks
of oxidation and short-circuiting, and in watertight
and accessible boxes located outside volume 0 of
the swimming pool as per the French NF C 15-100
standard or equivalent standard in the country of
use.
1.1.5
Earthing
In compliance with the French NF C 15-100 standard
or equivalent, it is imperative that all pools be
fitted with earthing in compliance with standard
requirements to evacuate any stray currents that
would exacerbate metal oxidation phenomena.
Consult the current electric standards and in
particular NF C 15-100.
1.1.6
Cable exit
Fig. 2
Exit these connecting cables from the slatted cover
stand (motor side) respecting the X measurement
(table below) from the centre of the pool in the
alignment of the rear coping of the pool for 90°
corner coping. If necessary advance them by the
distance of the radius of the curved part of the
pool's angle.
Pool (m)
Bench length (m)
X (m)
2 to 3.03
3.25
1.57
3.03 to 3.53
3.75
1.82
3.53 to 4.03
4.25
2.08
4.03 to 4.53
4.75
2.33
4.53 to 5.03
5.25
2.58
X
Centre Bassin
X
Pool centre
Fig. 2
Important: if the option of the box adjoining the
bench is present, take into account and remove the
0.75 cm box overhang from the bench length.
Fig. 1
230 V 50 Hz
30 mA
3 x 2.5 mm²
10A
0 m < D < 15 m → 2 x 4 mm
2
15 m < D < 30 m → 2 x 6 mm
2
2 x 1.5 mm
2
D
2 m
2.5 m
1.5 m
1.5 m
0
1
2
2