21/24 - Installation instructions for the BANC D.sign above water automatic slatted safety cover

21

Notice MHE24A-150 

Réf : KAEL156 

Notice de raccordement 

 

Consigne d’installation et de sécurité : 

 

L’installation du coffret électrique doit être réalisé par un personnel électricien qualifié et doit 

respecter la norme d’installation en vigueur en France NF C15-100. 

 

Coffret électrique sous tension, couper l’alimentation avant toute intervention.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plan de câblage 

 

 

 

 

On/off 

switch

On/off switch

Power supply

MHE24A-150 box

KAEL156

Power supply

Power supply

Wiring diagram

Contact sel

Connection 

terminal

Key-operated 

switch

Open request

Close request

Contact sel 

output

Open/closure 

command input

Relay 

board

Slatted cover motor

MHE24A-150 instructions

Ref.: KAEL156

Connection instructions

Installation and safety instructions: 

The electric box installation should be carried out by a qualified electrician and comply with the 

applicable installation standard which is NF C15-100 in France.

Live electric box, cut off the power before any work on it.

Содержание ABRIBLUE BANC D.SIGN

Страница 1: ...EN 04 2022 ABOVE WATER SLATTED SAFETY COVER Installation manual Please read carefully and keep available for later use 04 2022 Version BANC D SIGN S l a t t ed cover s sta n da r d Compliant with the...

Страница 2: ...the result of AS POOL s experience in manufacturing automatic slatted covers since 1995 It will allow users to make the best use of this product which should give compete satisfaction Compliant with t...

Страница 3: ...ssembling the slats 6 Limit switch adjustments 6 1 End of unrolling 11 6 2 Fixing the slat cover to the roller shaft 11 6 3 Adjustment of the end of rolling stop 11 6 4 Refitting the elements 11 7 Dec...

Страница 4: ...ort circuiting and in watertight and accessible boxes located outside volume 0 of the swimming pool as per the French NF C 15 100 standard or equivalent standard in the country of use 1 1 5 Earthing I...

Страница 5: ...sure the distance B1 between 1 and 4 1 3 7 Measure the distance B2 between 2 and 3 1 3 8 If the B1 and B2 measurements are equal continue with the next step otherwise correct the position of markers 3...

Страница 6: ...ngth L in order to allow the slats to move from the roller shaft to the pool without rubbing against the coping which could break the caps x x L 4 5 6 7 8 9 10 11 12 13 14 15 X 290 300 310 320 330 340...

Страница 7: ...rite down your reserves on the transport documents e g burst pack The words subject to unpacking alone are null and void Send a registered letter with acknowledgement of receipt to the transporter wit...

Страница 8: ...ced by 150 mm compared to the rear coping edge overhang or the end of a possible radius 3 1 6 Only fix to the ground after having carried out all the adjustments and checks and advance the bench onto...

Страница 9: ...REFERTOTHEATTACHEDWIRINGDIAGRAMS 4 1 1 Connect the 230 V power supply cable in the electric box to the terminal marked T for the earth P for the phase and N for the neutral 4 1 2 Connect the 2 power w...

Страница 10: ...er instructions 4 3 Roller rotation test Fig 19 Test the tube s rotation in both directions The slats should roll by passing over the roller shaft If the movement is not in the required direction reve...

Страница 11: ...3 screws and the 2 plastic rivets 6 4 2 Then refit the duckboards on the top and the upper panel if the bench has one 6 Limit switch adjustments 6 1 End of unrolling Fig 21 6 1 1 Find the 2 limit swi...

Страница 12: ...tart by raising the back and pivoting it completely Fig 28 7 Deckchair option The bench is design to support a maximum load of 100 kg m 7 1 Handle installation 7 1 1 Fig 24 and 25 Start by raising the...

Страница 13: ...ack unclip the deckchair back bar to place it in the rack Fig 32 Fig 33 Fig 29 7 2 2 Fig 30 Remove the duckboard deckchair assembly Fig 30 7 2 3 Fig 31 Remove the screen under the deckchair in the ord...

Страница 14: ...e from the motor 9 1 Use 9 1 1 Fig 37 Open the box by lifting its end to store accessories Fig 37 9 1 2 Fig 38 A gas cylinder will help you lift the box to mid height and will also keep the box open F...

Страница 15: ...2 Removing the box duckboard Fig 39 If you want to remove it you must be in box opening mode to remove the cylinder Unscrew the M5 nut from the cylinder ball and socket Detach the cylinder from the d...

Страница 16: ...stud 5 5 x 40 self tapping screw Fig 46 12 1 3 Fig 47 Using a size 8 hexagonal bit drill and screw the 2 assembled screws with the studs on the markings taking care not to slip and scratch the side pa...

Страница 17: ...ndicated on the box diagram in the appendix 13 1 2 Turn the switch on the electric box to stop Off or 0 13 1 3 Disconnect the 2 wires connecting the box to the roller motor These two wires are connect...

Страница 18: ...the key is turned first in one direction and then in the other 13 3 2 On the screw terminals marked 1 2 3 4 13 3 3 Measure 12 V or 24 V DC between the and 13 3 4 Measure 12 V or 24 V DC between 3 and...

Страница 19: ...e pool is visible and check that there are no bathers in the pool when closing the cover The unrolling operation stops when the key is released The key can be removed from the control box The cover ro...

Страница 20: ...otor 24VDC Moteur Motor 1 2 3 4 C M 2 1 Cl Key Moteur Volet Entr e Input 24VDC Cl Key Moteur Motor Output Slow Mode Carte de communication Communication card CONTROL BOX COFFRET DE COMMANDE MHE24A 150...

Страница 21: ...ute intervention Plan de c blage On off switch On off switch Power supply MHE24A 150 box KAEL156 Power supply Power supply Wiring diagram Contact sel Connection terminal Key operated switch Open reque...

Страница 22: ...Installation instructions for the BANC D sign above water automatic slatted safety cover 22 24 22 24VDC Motor 0VDC Motor key Opening Closure BOX Motor...

Страница 23: ...for the BANC D sign above water automatic slatted safety cover 23 Coffret commande Aero C blage avec option led LED BOX 24VDC Motor 0VDC Motor Opening Closure key LED Motor AERO board LED power board...

Страница 24: ...BANC D sign above water automatic slatted safety cover 24 24 24 Product BANC D sign Company AS POOL Address ZAC de la Rouvelli re F 72700 SPAY LE MANS Phone 33 0 811 901 331 Fax 33 0 243 479 850 cont...

Страница 25: ...Safety instructions and user guide for the automatic pool cover Please read carefully and keep available for later use 01 2022 Version AE 12 018 12EN 01 2022 Slatted covers...

Страница 26: ...hildren Drowning happens very quickly Children close to a pool require constant monitoring and active supervision even if they can swim The physical presence of a responsible adult is indispensable wh...

Страница 27: ...he sound level generated by the automatic safety cover when running is 65 dB 0 0UV FERM The cover is controlled using a control that is locked using a key or an access code placed in the immediate poo...

Страница 28: ...s complete 6 Keep a permanent view over the cover and the pool while it is moving Make sure to keep people away from the roller 7 Keep the control key or the remote control out of the reach of childre...

Страница 29: ...use brownish stains to appear on the slats This natural phenomenon is not covered by our guarantee 3 Advice for use Always check that the pool water level remains constant and in compliance with the m...

Страница 30: ...er level regulation overflow not clogged automatic filling correctly set Make sure that the area where the cover motor is located is fitted with a drain preventing the motor from being submerged at al...

Страница 31: ...on the specificities of the pool AS POOL does not communicate directly with pool owners Have the automatic cover serviced by a swimming pool professional we recommend your swimming pool installer whos...

Страница 32: ...t the batteries must be disconnected and stored in a dry place When putting back into service let the batteries charge a half day of sunlight before operating the cover 7 Guarantee Our one year guaran...

Страница 33: ...Blue PVC Light grey PVC Galet grey PVC Blue tinted two ply PVC Clear polycarbonate Blue tinted translucent polycarbonate Blue tinted two ply polycarbonate Mother of pearl tinted two ply polycarbonate...

Страница 34: ...ic box check the 10A 30mA ground fault circuit breaker The on off button on the box is ON Fuses are in good condition 12 V or 24 VDC voltage on the motor power terminals when the key is turned Continu...

Отзывы: