- 23 -
SUPER P
www.NewLeader.com
(800) 363-1771
301321-AA-I
Installation Instructions
Pump and truck requirements must be determined prior to installation of the spreader�
Hydraulic Requirements
Hydraulics
GPM (LPM)
(Gallons/Liters per Minute)
Maximum
Pressure (PSI)
Super P (Single Hydraulics)
9 (34)
1500
Super P (Dual Hydraulics)
12(45)
Recommended sequence of installation is:
1�
Mounting of pump and pump drive�
2�
Installation of spreader�
3�
Installation of cab controls�
4�
Connection of hydraulic and electrical systems�
5�
Filling of hydraulic reservoir and initial lubrication�
6�
Checking installation for leaks and proper functioning�
7�
Installation of optional parts�
Truck Requirements
Before mounting the spreader on a truck, the following major questions must be considered:
1� Is the CA (Cab to Axle) dimension of the truck correct for the length of the spreader?
The Dimensions and Capacities chart in the operator’s manual will assist in matching spreader to
truck�
2� Is the truck’s GAWR (Gross Axle Weight Rating) and the GVWR (Gross Vehicle Weight Rating) adequate
to carry the fully loaded spreader?
Refer to your Hi-Way dealer to find the GAWR and GVWR for most trucks, and how to calculate the
weight distribution on each axle and total loaded vehicle weight�
Truck Frame Length
Refer to “Dimensions & Capacities” section in the operator’s manual for approximate length from the
rear of the cab to the rear end of the frame� Shorten truck frame as necessary, making sure to follow
truck manufacturer’s specifications so as not to void truck warranty.
Содержание Hi-Way SUPER P
Страница 5: ...5 SUPER P www NewLeader com 800 363 1771 301321 AA I Notes This page is intentionally left blank...
Страница 6: ...Insert Current HI WAY Warranty Warranty...
Страница 20: ...20 www NewLeader com 800 363 1771 301321 AA I SUPER P Safety Decals Continued 55630 D...
Страница 22: ...22 This page is intentionally left blank www NewLeader com 800 363 1771 301321 AA I SUPER P Notes...