Switching Commands
175
ProSafe Managed Switch
lldp notification-interval
Use this command to configure how frequently the system sends remote data change
notifications. The
<interval>
parameter is the number of seconds to wait between sending
notifications. The valid interval range is 5-3600 seconds.
Default
Format
lldp notification-interval
<interval>
Mode
no lldp notification-interval
Use this command to return the notification interval to the default value.
Format
no lldp notification-interval
Mode
clear lldp statistics
Use this command to reset all LLDP statistics, including MED-related information.
Format
clear lldp statistics
Mode
clear lldp remote-data
Use this command to delete all information from the LLDP remote data table, including
MED-related information.
Format
clear lldp remote-data
Mode
show lldp
Use this command to display a summary of the current LLDP configuration.
Format
show lldp
Mode
5
Global Config
Global Config
Privileged Exec
Global Config
Privileged Exec
Term
Definition
Transmit
Interval
How frequently the system transmits local data LLDPDUs, in seconds.
Transmit Hold
Multiplier
The multiplier on the transmit interval that sets the TTL in local data LLDPDUs.