Log Messages
706
ProSafe Managed Switch
Table 16. WEB Log Messages
Component
Message
Cause
WEB
Max clients exceeded
This message is shown when the maximum
allowed java client connections to the
switch is exceeded.
WEB
Error on send to sockfd XXXX, closing
connection
Failed to send data to the java clients
through the socket.
WEB
# (XXXX) Form Submission Failed. No
Action Taken.
The form submission failed and no action is
taken. XXXX indicates the file under
consideration.
WEB
ewaFormServe_file_download() - WEB
Unknown return code from tftp download
result
Unknown error returned while downloading
file using TFTP from web interface
WEB
ewaFormServe_file_upload() - Unknown
return code from tftp upload result
Unknown error returned while uploading file
using TFTP from web interface.
WEB
Web UI Screen with unspecified access
attempted to be brought up
Failed to get application-specific
authorization handle provided to
EmWeb/Server by the application in
ewsAuthRegister(). The specified web
page will be served in read-only mode.
Table 17. CLI_WEB_MGR Log Messages
Component
Message
Cause
CLI_WEB_MGR
File size is greater than 2K
The banner file size is greater than 2K
bytes.
CLI_WEB_MGR
No. of rows greater than allowed maximum
of XXXX
When the number of rows exceeds the
maximum allowed rows
Table 18. SSHD Log Messages
Component
Message
Cause
SSHD
SSHD: Unable to create the global (data)
semaphore
Failed to create semaphore for global data
protection.
SSHD
SSHD: Msg Queue is full, event = XXXX
Failed to send the message to the SSHD
message queue as message queue is full.
XXXX indicates the event to be sent