Utility Commands
596
ProSafe Managed Switch
sflow receiver
Use this command to configure the sFlow collector parameters (owner string, receiver
timeout, max datagram size, IP address, and port).
Format
sflow receiver <
rcvr_idx
> owner <
owner-string
> [timeout
<
rcvr_timeout
> | notimeout] max datagram <
size
> ip/ipv6 <
ip
> port
<
port
>
Mode
no sflow receiver
Use this command to set the sFlow collector parameters back to the defaults.
Format
no sflow receiver <
indx
> {ip <
ip-address
> | maxdatagram <
size
> | owner
<
string
> timeout <
interval
> | port <
14-port
>}
Mode
Global Config
Field
Description
Receiver Owner
The identity string for the receiver, the entity making use of this sFlowRcvrTable entry.
The range is 127 characters. The default is a null string. The empty string indicates that
the entry is currently unclaimed and the receiver configuration is reset to the default
values. An entity wishing to claim an sFlowRcvrTable entry must ensure that the entry is
unclaimed before trying to claim it. The entry is claimed by setting the owner string to a
non-null value. The entry must be claimed before assigning a receiver to a sampler or
poller.
Receiver
Timeout
The time, in seconds, remaining before the sampler or poller is released and stops
sending samples to receiver. A management entity wanting to maintain control of the
sampler is responsible for setting a new value before the old one expires. The allowed
range is 0-4294967295 seconds. The default is zero (0).
Receiver Max
Datagram Size
The maximum number of data bytes that can be sent in a single sample datagram. The
management entity should set this value to avoid fragmentation of the sFlow datagrams.
The allowed range is 200 to 9116). The default is 1400.
Receiver IP
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow datagrams will be sent. The
default is 0.0.0.0.
Receiver Port
The destination Layer4 UDP port for sFlow datagrams. The range is 1-65535. The
default is 6343.
Global Config