35
Ness SmartBell IP Intercom Installation and Users Manual.(series 2)
Version 1.5.4
Indoor Phone / Master Station, 10” tablet (101-132B) installation
NOTE: Each Indoor Phone / Room station must be wired direct back to the eGateway
Indoor Port using suitable Cat5e / Cat6 Data cable. Do not connect these units to your
customers LAN data network.
Powering the 10 inch indoor phone externally
NOTE:
When powering the 10” indoor phone with the Ness PoE LAN Switch (101-363) it requires
12/24VDC to power it.
Therefore DO NOT use the 48V power supply that comes with the switch. Instead please use a
24Volt power supply (101-134) (Sold separately) with the PoE LAN switch (101-363).
Powering up the 10 inch touch screen with the wrong voltage will void your warranty.
Note: The Indoor & Outdoor ports on the eGateway module are
POE (Power over Ethernet). Therefore Indoor / Master Room
stations and Outdoor Phones / Door Stations connected to these
ports, are powered off these ports, therefore no need to additional
power supplies.
“However If more than 2 devices are needed to be installed you
can use LAN1 and LAN 2 ports on the eGateway, however
external power supplies will be required to power these additional
modules connected to LAN 1 & LAN 2 ports
Содержание SmartBell
Страница 19: ...19 Ness SmartBell IP Intercom Installation and Users Manual series 2 Version 1 5 4 Background Settings ...
Страница 56: ...56 Ness SmartBell IP Intercom Installation and Users Manual series 2 Version 1 5 4 Function chart ...
Страница 63: ...63 Ness SmartBell IP Intercom Installation and Users Manual series 2 Version 1 5 4 Set the DDNS to WiFi router ...
Страница 73: ...73 Ness SmartBell IP Intercom Installation and Users Manual series 2 Version 1 5 4 NOTES ...