29
Ness SmartBell IP Intercom Installation and Users Manual.(series 2)
Version 1.5.4
Installation steps – Device Installation
Installing the Outdoor Phone (ODP)
Surface Mount Flush Mount
NOTE: Each Outdoor Phone / Door station must be wired direct back to the eGateway
Outdoor Port using suitable Cat5e / Cat6 Data cable.
Do not connect these units to your customers LAN data network.
Note: The Indoor & Outdoor ports on the eGateway
module are POE (Power over Ethernet). Therefore
Indoor / Master Room stations and Outdoor Phones /
Door Stations connected to these ports, are powered off
these ports, therefore no need to additional power
supplies.
“However If more than 2 devices are needed to be
installed you can use LAN1 and LAN 2 ports on the
eGateway, however external power supplies will be
required to power these additional modules connected
to LAN 1 & LAN 2 ports