18
MaxiMailer HD Operator Manual
Hopper fine Tuning (DTI,
feeder and feeder folder)
From here you can adjust
hopper settings. Press on the
appropriate hopper, and on
Document fine Tuning
to
display further information.
You can select:
a: Whether the unit is turned
on or off. Select ‘Off’ if, for
example, you wish to leave
the hopper loaded, but
temporarily disable it for the
job.
b: Whether or not doubles detect is enabled. Select ‘Off’ if, for
example, the documents being run are substantially different from the
calibration document, such as abnormally dark with heavy printing.
c: Separator Position (feeder or tower feeder only): if you select a
different setting from the one displayed (as calculated by the software)
ensure the physical separator is set to the same setting, or a warning
will be flagged with the first insertion cycle only.
Note: this setting is
duplicated in the ‘Configuration’ screen (see page 29). Whichever is
set most recently takes precedence.
d: The setting of the amount of document deskew required. Note a
higher level will slow the machine more.
e: Calibrate Reader: Only available if OMR head is fitted. Click the button
and follow the instructions for calibration.
f: Reader On/Off: Only available if a barcode head is fitted. Switching the
reader on or off is required when aligning.
g: Press the button and adjust width and depth if actual document
varies from the settings shown.
Warning: if the same document is
used on other jobs as well, the same settings will be applied.
Important: All fine adustments apply only to the current job
and will not affect any other jobs.