31
4.4.4. System setting
Function: it is mainly for correction the position of suction nozzle.(Notice: In case change by
mistake,we ‘ve locked it by password. It can be changed by clicking the button of Password
change and then insert password. Strongly recommend operating it under our engineer’s
guidance).
(1) Default parameters 1 setting:
Default speed: placement head movement speed under overall situation, priority is not as fast
as speed set in stacks.
Vibration feeder frequency: setting the frequency of vibration feeder. Discharge state will be
more stable if frequency high.
Vibration feeder strength: it depends on the component, if component too small and strength
set high it will shake out the component easily, of course if strength small, the discharging
speed will be slower.
(2)
Nozzle Jointly Alignment setting:
Click test button and go into interface below: