PROBLEM

POSSIBLE CAUSE

SOLUTION

LOW  

QUANTITY OF 

PRODUCT 

WATER 

FROM  

HOLDING  

TANK

Feed Water Valve is plugged or closed.

Open Valve or unclog.

Clogged Sediment Pre-Filter or  

Activated Carbon Pre-Filter.

Replace filters.

Low water pressure.

Feed Water pressure  

must be above 40 psig.

R.O. Membrane is fouled.

See Feed Water operating limits. 

Correct cause of fouling, replace Membrane.

Plugged In–Line Activated 

Carbon Post-Filter.

Replace Post-Filter.

Air precharge pressure in  

Holding Tank is too high.

Empty water from Holding Tank, 

and with the faucet open, adjust air 

pressure to 5–7 psig (35–48 kPa) range.

Air precharge is too low.

Air bladder in the Holding Tank is ruptured.

Replace tank.

Holding Tank Valve is closed.

Open Valve.

No drain flow, the Drain Restrictor is plugged.

Clear or replace Drain Restrictor.

No drain flow, the drain orifice in the Dispensing 

Faucet is plugged.

Clear or replace the Dispensing Faucet.

The Check Valve is stuck.

Free check.

The ASO Valve is malfunctioning.

In-Line Activated Carbon Post-Filter is plugged.

LOW  

PRESSURE  

AT THE 

DISPENSING 

FAUCET

In-Line Activated Carbon Post  

Filter is plugged.

Replace Post-Filter.

Air precharge in the Holding Tank is too low.

Empty water from Holding Tank and with  

the faucet open, adjust the air pressure  

to 5–7 psig (35–48 kPa) range.

Check for leakage at the Air Valve Stem.

Holding Tank Valve is partially closed.

Open Valve.

The Dispensing Faucet is out of  

adjustment or faulty.

Allow Holding Tank to refill (adding a second  

Holding Tank will increase storage capacity).

Low Water Production.

See Low Quantity of Product Water from  

Holding Tank section above

HIGH TOTAL 

DISSOLVED  

SOLIDS (TDS)  

IN THE  

PRODUCT  

WATER

Clogged Sediment Pre-Filter or  

Activated Carbon Pre-Filter.

Replace Filters.

Low Water Pressure.

Feed Water Pressure must be above 40 psig.

Check Feed Water Valve.

R.O. Membrane O–ring is crimped.

Check O–ring.

R.O. Membrane brine seal is not 

sealing up into the manifold head.

Check the brine seal.

R.O. Membrane has expired.

If Membrane life is unusually short, find and  

correct the problem. Replace Membrane.

SECTION VII. TROUBLE SHOOTING GUIDE

17

Содержание RO-4300Rx-DLX

Страница 1: ...The High Efficiency Reverse Osmosis Drinking Water System Installation Operation And Service Manual DLX...

Страница 2: ...ICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM Systems certified for cyst reduction may be used on disinfected water that may contain filterable...

Страница 3: ...or substances that contribute to tastes and odors IN LINE ACTIVATED CARBON POST FILTER The In Line Activated Carbon Post Filter is located after the Holding Tank and has been designed to reduce the ta...

Страница 4: ...ct 3 8 Blue 6 7 8 Polytube Tee Stage 3 Carbon Post Filter Housing Stage 2 Reverse Osmosis Membrane Housing Stage 1 Sediment Carbon Pre Filter Housing Locate Drain Clamp Above P Trap Feed Water Valve C...

Страница 5: ...this manual Cover RO Manifold Drinking Water Holding Tank Mount Holding Tank On Shelf Or Strap Between Floor Joists Shelf or straps not included Stage 3 Activated Carbon Post Filter Housing Stage 2 Re...

Страница 6: ...ble to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influent water to...

Страница 7: ...ws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing B TOOLS RECOMMENDE...

Страница 8: ...as it will extend the life of the R O Membrane 3 R O Manifold Assembly The manifold can be installed on either the right or left side of the under sink area or a cabinet The right side is recommended...

Страница 9: ...sher Rubber Connector Faucet 3 8 x 7 16 Drain Line From Air Gap To Drain 3 8 Black Tubing Drain Line To Air Gap 1 4 Black Tubing AIR GAP ONLY GRINDING WHEEL Sink Top Metal Porcelain CAUTION Be careful...

Страница 10: ...Punch 5 Set the punch and turn the nut with a wrench to cut the hole D PREPARE THE R O AIR GAP FAUCET ASSEMBLY FOR INSTALLATION 1 Using the diagram in Figure 3 assemble the Air Gap Spigot with all th...

Страница 11: ...ion nut on the feed water supply valve Do not over tighten 10 Reconnect the riser tube to the other end of the feed water supply valve Do not over tighten 11 Fully insert the red 1 4 tube into the spe...

Страница 12: ...Faucet Route the tubing to the Drain Clamp and trim to length NOTE When cutting the polytubing make clean square cuts failing to do so could result in poor connections and possible leaks CAUTION The...

Страница 13: ...hen press firmly again to insure proper seating 19 Locate the White tubing Remove the yellow plug from the fitting labeled Out on the manifold and insert the tubing 20 Locate the 3 8 Blue Product Wate...

Страница 14: ...OSE the Feed Water Valve and open the Dispensing Faucet Allow the Holding Tank to completely drain then remove the Sediment Carbon Filter Housing the farthest of the three from the In Out ports empty...

Страница 15: ...ion it is better to empty the Holding Tank and allow the system to produce fresh water for use If the system is not used for 3 4 weeks or longer it is a good idea to re sanitize the system and to chan...

Страница 16: ...the Faucet in the following order close the Faucet and open the Holding Tank Valve When the Faucet is first opened expect air and carbon fines very fine black powder from the new Post Filter to be ri...

Страница 17: ...tem A The Permeate pump brine side should be installed between the R O System and the air gap faucet connection From the R O plug black tube into BRINE IN port B Connect a new length long enough to re...

Страница 18: ...ASO Valve is malfunctioning In Line Activated Carbon Post Filter is plugged LOW PRESSURE AT THE DISPENSING FAUCET In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in t...

Страница 19: ...gases in the Feed Water Pretreat Feed Water to remove dissolved gases Increase in Product Water TDS See high TDS in the Product Water section AMBER LIGHT ON WATER QUALITY MONITOR System not being used...

Страница 20: ...EXPLODED VIEW AND PARTS LIST 19A Water Quality Test Kit 23 Nitrate Nitrite Test Kit Optional Deluxe Components 17 19 20 14 13 12 11 16 18 10 9 15 1 2 3 4 5 6 7 8 24 25 19...

Страница 21: ...O Membrane 50 gpd 189 lpd Part No CLK TF 50 13 Housing O Ring 14 Housing 15 Water Quality Monitor Board w Probes 16 Drain Restrictor 50 GPD 189 lpd Green 17 Cover 18 Activated Carbon Post Filter Part...

Страница 22: ...t and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply...

Отзывы: