F. START UP

 

At time of start up and each time the filters are changed the system should be sanitized (also see Operation  

and Maintenance Sec. V).

SECTION IV. INSTALLATION STEPS

1.  Sanitizing the system. Use a drip pan to aid clean–up.

NOTE:

 The system should be sanitized BEFORE installing 

the Sediment/Carbon Pre-Filter, the Activated Carbon 

Post-Filter or the R.O. Membrane.

•  Use a good quality unscented 5¼% liquid chlorine 

household bleach.

•  Open the Dispensing Faucet and open the Holding 

Tank Shut–Off Valve (the handle should be parallel 

with the valve body).

•  Remove the plug on the underside of the manifold 

labeled “SEDIMENT/CARBON”. Pour one capful of 

bleach (this is approximately 2 tsp. or 10 ml) into one 

of the white Housings. Insert a Housing O–ring into the 

Housing groove, (press firmly in place). Engage and 

firmly tighten the Housing hand tight only.

•  Remove the plugs labeled “MEMBRANE” and 

“ACTIVATED CARBON” from the underside of the 

manifold. To each of the remaining white Housings, 

add one capful of bleach. Insert a Housing O–ring, 

engage and firmly tighten the Housings hand  

tight only.

•  Slowly open the Feed Water Valve  

(turning counter clockwise).

•  As soon as the water begins to come out of  

the Dispensing Faucet, close the Faucet.

•  Let stand for 15 minutes. 

 

NOTE:

 During this time, check the system  

carefully for leaks.

•  At the end of 15 minutes, CLOSE the Feed Water  

Valve and open the Dispensing Faucet.

•  Allow the Holding Tank to completely drain, then 

remove the Sediment/Carbon Filter Housing (the 

farthest of the three from the In–Out ports), empty, 

and install the Sediment/Carbon Pre-Filter. Firmly 

tighten the Housing hand tight only.

•  Remove the Activated Carbon Filter Housing  

(the closest of the three to the In–Out ports),  

empty, and install the Activated Carbon Post-Filter. 

Firmly tighten the Housing hand tight only.

2.  Installing the R.O. Membrane:

•  Remove the R.O. Membrane Housing,  

(the middle one), and empty.

•  Insert the Membrane up into the manifold.  

(The O–rings should be up toward the manifold.)  

Check the Housing O–ring for proper position in  

its groove, engage and firmly tighten the Housing  

hand tight only.

3.  Installing the R.O. Membrane:

•  Slowly open the Feed Water Valve fully  

counter clockwise.

•  The Holding Tank Valve should be open.

•  Check the Air Gap Window on the Dispensing  

Faucet to be sure that the drain water is flowing.  

The R.O. System is now making water.

•  Do not open the Faucet for at least 8 hours.

•  Do not use the first three full tanks of water. 

 

CAUTION:

 The R.O. Membrane is shipped with a 

preservative in it. To ensure proper rinsing of the  

R.O. Membrane it is important to wait at least 8  

hours before emptying each tank. 

 

When the Faucet is first opened, expect air  

and carbon fines (very fine black powder) from  

the In–Line and Activated Carbon Post-Filters to  

be rinsed out. This is normal for the first tank of  

water or after the Activated Carbon Post-Filters 

 are changed.

13

Содержание RO-4300Rx-DLX

Страница 1: ...The High Efficiency Reverse Osmosis Drinking Water System Installation Operation And Service Manual DLX...

Страница 2: ...ICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM Systems certified for cyst reduction may be used on disinfected water that may contain filterable...

Страница 3: ...or substances that contribute to tastes and odors IN LINE ACTIVATED CARBON POST FILTER The In Line Activated Carbon Post Filter is located after the Holding Tank and has been designed to reduce the ta...

Страница 4: ...ct 3 8 Blue 6 7 8 Polytube Tee Stage 3 Carbon Post Filter Housing Stage 2 Reverse Osmosis Membrane Housing Stage 1 Sediment Carbon Pre Filter Housing Locate Drain Clamp Above P Trap Feed Water Valve C...

Страница 5: ...this manual Cover RO Manifold Drinking Water Holding Tank Mount Holding Tank On Shelf Or Strap Between Floor Joists Shelf or straps not included Stage 3 Activated Carbon Post Filter Housing Stage 2 Re...

Страница 6: ...ble to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influent water to...

Страница 7: ...ws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing B TOOLS RECOMMENDE...

Страница 8: ...as it will extend the life of the R O Membrane 3 R O Manifold Assembly The manifold can be installed on either the right or left side of the under sink area or a cabinet The right side is recommended...

Страница 9: ...sher Rubber Connector Faucet 3 8 x 7 16 Drain Line From Air Gap To Drain 3 8 Black Tubing Drain Line To Air Gap 1 4 Black Tubing AIR GAP ONLY GRINDING WHEEL Sink Top Metal Porcelain CAUTION Be careful...

Страница 10: ...Punch 5 Set the punch and turn the nut with a wrench to cut the hole D PREPARE THE R O AIR GAP FAUCET ASSEMBLY FOR INSTALLATION 1 Using the diagram in Figure 3 assemble the Air Gap Spigot with all th...

Страница 11: ...ion nut on the feed water supply valve Do not over tighten 10 Reconnect the riser tube to the other end of the feed water supply valve Do not over tighten 11 Fully insert the red 1 4 tube into the spe...

Страница 12: ...Faucet Route the tubing to the Drain Clamp and trim to length NOTE When cutting the polytubing make clean square cuts failing to do so could result in poor connections and possible leaks CAUTION The...

Страница 13: ...hen press firmly again to insure proper seating 19 Locate the White tubing Remove the yellow plug from the fitting labeled Out on the manifold and insert the tubing 20 Locate the 3 8 Blue Product Wate...

Страница 14: ...OSE the Feed Water Valve and open the Dispensing Faucet Allow the Holding Tank to completely drain then remove the Sediment Carbon Filter Housing the farthest of the three from the In Out ports empty...

Страница 15: ...ion it is better to empty the Holding Tank and allow the system to produce fresh water for use If the system is not used for 3 4 weeks or longer it is a good idea to re sanitize the system and to chan...

Страница 16: ...the Faucet in the following order close the Faucet and open the Holding Tank Valve When the Faucet is first opened expect air and carbon fines very fine black powder from the new Post Filter to be ri...

Страница 17: ...tem A The Permeate pump brine side should be installed between the R O System and the air gap faucet connection From the R O plug black tube into BRINE IN port B Connect a new length long enough to re...

Страница 18: ...ASO Valve is malfunctioning In Line Activated Carbon Post Filter is plugged LOW PRESSURE AT THE DISPENSING FAUCET In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in t...

Страница 19: ...gases in the Feed Water Pretreat Feed Water to remove dissolved gases Increase in Product Water TDS See high TDS in the Product Water section AMBER LIGHT ON WATER QUALITY MONITOR System not being used...

Страница 20: ...EXPLODED VIEW AND PARTS LIST 19A Water Quality Test Kit 23 Nitrate Nitrite Test Kit Optional Deluxe Components 17 19 20 14 13 12 11 16 18 10 9 15 1 2 3 4 5 6 7 8 24 25 19...

Страница 21: ...O Membrane 50 gpd 189 lpd Part No CLK TF 50 13 Housing O Ring 14 Housing 15 Water Quality Monitor Board w Probes 16 Drain Restrictor 50 GPD 189 lpd Green 17 Cover 18 Activated Carbon Post Filter Part...

Страница 22: ...t and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply...