4.2.23 OTTmr
Menu for setting the overtime timer. If the unit needs to be used after the weekly timer
has expired, the unit can be turned on for a set number of hours by pressing the external
standby button. When the OTTmr expires, the machine goes back into Off mode.
If the unit is in Off mode and the weekly timer is not used, quickly pressing the external
standby button (less than 2 seconds) puts the unit into Standby mode for the time set in ‘T’,
for example two hours. See the figure below.
If the unit is in Standby mode and the weekly timer is not used, quickly pressing the
external standby button (less than 2 seconds) puts the unit into Off mode after the time set
in ‘T’,for example two hours. See the figure below.
If the weekly timer is being used, quickly pressing the external standby button (less than
2 seconds) keeps the unit into Standby mode for an additional two hours after the closing
time set in the weekly timer, see Section
‘4.2.2 Set the weekly timer’
.
To reset OTTmr so that the time is not extended, press the external standby button longer
than 2 seconds and then release.
ESC
OK
OTTmr
1/1
T = 2:00h
Ta = 00:00s
T=02:00h: Extra time before the unit goes into Off mode. The default
setting is 2 hours.
Ta=00:00: The elapsed time since the overtime timer started.
4.2.24 FlushTmp
Menu for temperature settings for regulating the fan’s outgoing air with the help of the
flush valve (SFV1). When the air temperature of outgoing air reaches the value set by
FlushTMP, the flush valve (SFV1) opens to let in air in the system to reduce the outgoing
air’s temperature.
Note that when the valve is open, the vacuum level from the workstations pipes leading
to the main pipe can be reduced. However, the flow in the main pipe partially increases
flushing out dirt and debris.
The default settings for FlushTmp; FlushTmp is not activated:
ESC
OK
FlushTmp
1/1
On = 110
Off = 97
A = 0,25
B = -50
C = -50
On=110: The temperature limit that is set to open flushing valve 1
(SFV1). The default setting is 110°C (230ºF).
Off= 97 (207ºF): The temperature limit that is set to close the flush
valve. The default setting is 97°C (207ºF).
Ax=00:00: The current temperature of air exiting the system.
To activate FlushTmp, use the following settings:
ESC
OK
FlushTmp
1/1
On = 99
Off = 97
A = 0,25
B = -50
C = -50
On=99: The temperature limit that is set to open flushing valve 1
(SFV1). The default setting is 110°C (230ºF).
Off= 97 (207ºF): The temperature limit that is set to close the flush
valve. The default setting is 97°C (207ºF).
Ax=00:00: The current temperature of air exiting the system.