FlexPAK 800/1000
23
EN
Weekend or second shift setting
ESC
OK
WeekTmr
2/2
Off2
= -- : --
D3
= - - - - - - -
On3
= -- : --
Off3
= -- : --
Pulse = Off
D3 = _ _ _ _ _ SS: Default setting; Saturday and Sunday.
On3 = _ _: Default setting Time the unit set to ‘Stand By’ on chosen D3
days. Default setting is no preset time.
Off3 = The time the unit is set to ‘Off’ on chosen D3 days. Default setting
is no preset time.
Example
D3=_ _ _ _ _ SS
Saturday, Sunday
On3 = 09:00
Unit starts at 9:00 in the morning
Saturday, Sunday
Off3 = 13:00
Unit Stops at 13:00 in the afternoon
Saturday, Sunday
NOTE!
Pulse = Off: The pulse parameter must always be set to Off.
NOTE!
When the timer stops the unit and a valve at a workstation is in its open position,
the unit will start immediately once the timer puts the unit in standby mode.
It is not necessary to use the timer function. The function can be switched off by setting the
display to show only dashes. However, it is recommended that the timer function is used,
as this ensures that the unit is switched off even when a valve remains open, for example,
over night.
NOTE!
If the weekly timer has been activated, the amount of time the unit can be used
during the day before it automatically goes into Off mode can be extended if the optional
external standby button accessory is used, see Section
‘4.2.23 OTTmr’.
4.2.3
H-Meter 1
Menu for setting the service interval. The default value is 2000 hours.
ESC
OK
H-Meter
1/1
MI
=2000h:0m
OT
=0h:15m
MN
=1999h:45
MN Ext =2000
MI =2000 hours: The amount of time between service intervals.
4.2.4
SSR_Time
Menu for setting the SSR timer. The SSR timer is for the amount of time before the unit
goes from Idling mode to Standby mode when the pilot signal disappears.
ESC
OK
SSR_Time
1/1
T = 10:00m
Ta = 00:00
T=12:00 minutes: Time before SSR_Time is activated. The default
setting is 12 minutes. The minimum setting is 5 minutes.
Ta=00:00 minutes: The elapsed time since the pilot signal disappeared.
Содержание FlexPAK 800
Страница 2: ...FlexPAK 800 1000 2...
Страница 3: ...FlexPAK 800 1000 3 Figures 4 English 7...
Страница 5: ...FlexPAK 800 1000 5 2...
Страница 42: ...FlexPAK 800 1000 EN 42 PLC setting Default value Customer specific value...
Страница 43: ......
Страница 44: ...www nederman com...