FlexPAK 800/1000
17
EN
3.3.8
Alarm! Control Filter Clogged
The control filter is clogged and needs to be cleaned. It generally indicates a problem with
the main filter, or the control filter has been used too long and needs to be replaced. This
alarm is activated when CFDPS-Al has been activated for 5 seconds. Press the green OK
button
OK
to reset the alarm. See Section
‘4.2.16 CFDPS-Al’
.
ESC
OK
Alarm!
Control Filter
Clogged
Th 15:01
Unit is Stopped
Reset OK
3.3.9
TVFD Alarm! Upper Slide Not Closed
The TVFD Upper Solenoid Valve does not close while the dust bin is being emptied. TVFDC-
Al has expired. It can be caused by the following:
•
The upper slide valve has not been activated as it should.
•
Something can be stuck in the upper slide valve.
•
The compressed air pressure hose has either been disconnected or the compressed
air pressure is too low.
This message is only shown when TVFD advanced is activated.
ESC
OK
TVFD Alarm!
Upper slide
not closed
Th 11:23
Unit is Stopped
Reset OK==>
3.3.10 TVFD Alarm! Upper Slide Not Open
The TVFD Upper Solenoid Valve does not open while the dust bin is being emptied. TVFDO-
Al has expired. It can be caused by the following:
•
The upper slide valve has not been activated as it should.
•
Something can be stuck in the upper slide valve.
•
The compressed air pressure hose has either been disconnected or the compressed
air pressure is too low.
This message is only shown when TVFD advanced is activated.
ESC
OK
TVFD Alarm!
Upper slide
not open
Th 11:23
Unit is Stopped
Reset OK==>