FlexPAK 800/1000
11
EN
3.1.3
Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
ESC
OK
Running
kPA -20
DIRTm
00:00 s
OTTmr
00:00 h
Exhaust
Air Temp 60°C
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds. See also Section
‘4.2.7 DIR_Time’
.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
The temperature of the exhaust air is displayed at the bottom of the
display.
3.1.4
FlexPAK Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the time set in DIR_
Time, see Section
‘4.2.7 DIR_Time’
.
ESC
OK
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
TimeToStandby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes. See Section
‘4.2.4 SSR_Time’.
3.1.5
Filter Cleaning
The unit is cleaning its filter.
ESC
OK
Filter
Cleanining
Cycles
1
Elapsed
0
Clean
00:00 s
Charge
00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining time for cleaning pulse.
Charge: Remaining vacuum build time; the time until cleaning pulse is
activated.
3.1.6
Emptying preseparator
The time remaining until the preseparator bin is to be emptied.
ESC
OK
EMPTYING
Preseparator
Bin 1 08:00s
Bin 2 06:00s
Bin 1: The time remaining to empty the
preseparator
as set in BinOpnTm.
Bin 2: The time remaining for preseparator 2 to be emptied as set in
PresepTm.
3.1.7
Open Upper Slide Valve V12
The message appears when the TVFD Upper Solenoid Valve is expected to open. The timer
is set with TVFDO-Al, see Section
‘4.2.39 MFDPS-Al’
. If the timer elapses, the ‘TVFD Alarm!
Upper Slide Not Open is activated. This message is only shown when TVFD advanced is
activated.
ESC
OK
Open Upper
Slide Valve
Remaing time
06:00s
Remaining Time: The remaining time for the valve to open before the
alarm is activated.