FlexPAK 800/1000
EN
22
4.2.2
Set the weekly timer
Weekly timer sets the unit to “Stand By” mode and “Off Mode” at preset times. If the pilot
signal “PS” is active and the Vacuum unit is in Standby mode, the unit starts.
ESC
OK
Thu 10:45
2018-02-01
ESC
OK
Stop
>
Program
>
Setup
>
Network
>
Diagnos
ti
cs
>
ESC
OK
Set Parameter
Program Name
ESC
OK
WeekTmr
1/2
D1
= MTWTF
On1
= 00:00
Off1
= -- --
D2
= MTWTF
On2
= -- --
ESC
OK
WeekTmr
2/2
Off2
= -- --
D3
= - - - - -SS
On3
= -- --
Off3
= -- --
Pulse = Off
ESC
OK
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
ESC
OK
WeekTmr
>
PresepTm
>
MFDPS-Wr
>
MFDPS-FC
>
BLI-Empt
>
BLI-Wr
Z
Do the following to set the weekly timer:
1.
From the PLC status screen, press the down arrow to go to the date and time
screen.
2.
Press ‘Escape’
ESC
to go to the main menu.
3.
Press the down arrow to go to ‘Program’. Press ‘OK’
OK
to confirm.
4.
Select ‘Set Parameter’. Press ‘OK’
OK
to confirm.
5.
Use the up or down arrows
to find ‘WeekTmr’. Press ‘OK’
OK
to confirm.
6.
Use right, left, up and down arrows
to select a value and change
settings. Press ‘OK’
OK
to confirm.
NOTE!
There are several other input menus on the same level as the date and time screen.
If pressing the down arrow takes the PLC to one of those menus, use the left arrow
to get to the date and time screen.
Daily AM setting
ESC
OK
WeekTmr
1/2
D1
= - - - - - - -
On1
= -- : --
Off1
= -- : --
D2
= - - - - - - -
On2
= -- : --
D1: = MTWTF: Default setting; Monday, Tuesday, Wednesday, Thursday
and Friday.
On1 = Time the unit is set to ‘Standby’ at chosen D1 days. Default setting
is no preset time.
Off1 = The time the unit is set to ‘Off’ on chosen D1 days. Default setting
is no preset time.
Daily PM setting
ESC
OK
WeekTmr
1/2
D1
= - - - - - - -
On1
= -- : --
Off1
= -- : --
D2
= - - - - - - -
On2
= -- : --
D2 = MTWTF: Default setting; Monday, Tuesday, Wednesday, Thursday
and Friday.
On2 = Time the unit is set to ‘Standby’ at chosen D2 days. Default setting
is no preset time.
Off2 = The time the unit is set to ‘Off’ on chosen D2 days. Default setting
is no preset time.