© by N&W GLOBAL VENDING S.p.A.
39
12 2008 3335 00
belt errors
-
: (models with
multimax
trays only)
the machine sets the selections associated with the
faulty motor out of service in the following cases:
- faulty motor or not connected
- high current absorption (short-circuit)
- time out (the photocells fail to detect the product
passage within a well-defined time interval during the
dispensing cycle)
Electromagnet errors
-
: (models with
multimax
trays
only)
The machine sets the selection out of service when the
control electronics fails to detect the current passage in
the electromagnet operating the release jaws.
Softvend locked
-
: (models with
softvEnd
only)
it is due to a
softvEnd
mechanical lock: the machine is
put out of order.
Power on the machine once again to initialise
softvEnd
once again.
Dispensing compartment lock
:
- If the function “compartment release upon dispensing”
is enabled, the fault is signalled if the closing device
is not released and locked within a well-defined time
interval after the selection once again.
- If the function “out of service if open” is enabled, the
failure to lock the closing device is displayed to lock the
operation of the machine.
- If the function “out of service if open” is disabled, the
failure to lock the closing device is displayed.
automatically openable compartment
-
: due to a
failure of the motor intended to open the dispensing
compartment.
The machine is not locked by this failure. You can
manually open the compartment to take the products.
Safety temperature exceeded:
-
the temperature of the
trays for dispensing food products is 4°C higher than
the temperature set for:
- over 45 minutes after having loaded products.
- over 15 minutes during the normal operation mode.
This failure indicates that the preservation of
“food” products has been compromised. The
sale of “food” products in the vending machine is
inhibited.
f
ailurE
rEsEt
Function used to reset all current failures, if any.
m
otor
Errors
Use this function to display faulty motors for about 1
second.
All faulty motors are scrolled automatically.
Note:
If you power on the machine again, any motor that
may have jammed is found out as not available.
s
tatE
of
motors
Use this function to learn the failure that last occurred
on every single spiral even if the machine configuration
provides for an empty position.
a motor can be in one of the following states:
motor running;
-
motor not available; when the motor is not detected as
-
soon as you power on the machine.
motor disconnected; when a motor is detected as soon
-
as you power on, but not during the dispensing cycle
motor locked; when the positioning switch is not oper
-
-
ated within the “time out” time.
empty spiral; when the dispensed product is not de
-
-
tected when the dispensing control device is mounted
(photocells).
m
otor
Error
rEsEt
Function used to reset all current failures, if any.
H
istory
filE
of
failurEs
Use this function to display the history file of failures. The
history file shows the failure with the corresponding date
and time.
Содержание Samba Top
Страница 1: ...InstallaTIon OPERATION MaIntenANCE EN English Doc No H3335EN00 Edition 1 12 2008 Samba Top...
Страница 2: ......
Страница 5: ......
Страница 6: ......
Страница 68: ...Sx49600...