© by N&W GLOBAL VENDING S.p.A.
13
12 2008 3335 00
PoWEr oN
Whenever you power on the machine, the machine
electronics will:
check the number of trays you have actually connected
-
check whether the dispensing compartment or, as an
-
alternative, the motorised compartment is locked (if
available)
move the belts forwards to put the products close to the
-
release jaws after having closed the jaws (the models
with
multimax
trays only)
initialise
-
softvEnd
in the initial position (models with
softvEnd
only)
The display will show the following in sequence:
software release
-
presence of the photocells intended to detect the dis-
-
pensing cycle
number of trays you have actually connected
-
presence of the device intended to prevent the dis-
-
pensing compartment from opening
refrigerated box temperature measured by the probe
-
The cooling unit is dimensioned to guarantee 7°c at
the bottom of the box not later than 45 minutes af
-
ter having completed the load cycle if the machine
had already achieved its steady state.
If the machine had been powered off for a long
time, wait for the steady-state temperature to be
reached before inserting the products.
The manufacturer will disclaim all responsibility
for any damage caused by the inobservance of the
precautions mentioned above.
oPEraTiNg TEmPEraTurE
The machine can only work at a temperature between 5
and 34°C.
The refrigerated box temperature can be regulated be
-
tween 3.5 and 20 °C.
clEaNiNg aT rEgular iNTErValS
Use a lukewarm solution and non-aggressive detergents.
Rinse and dry carefully.
To clean metal parts, avoid using any abrasive or cor
-
rosive detergent as well as chips, steel wool, brushes or
common steel scrapers.
attention !!!
it is anyway forbidden to direct any water jet
against the machine
clEaNiNg THE VENTilaTioN gridS of
THE cooliNg SySTEm
Clean the ventilation grid of the cooling system at least
every 30 days by using a vacuum-cleaner or com
-
pressed air. Act as follows:
detach the vending machine from the supply mains and
-
remove the feet cover (unscrew the fastening screw)
extract the aspiration grid
-
after having cleaned the grids, re-assemble everything
-
by acting in the reverse order
attention!!!
it is forbidden to direct any water jet against the
machine.
Never forget to power off the machine before serv
-
icing.
The qualified personnel shall check the machine in
-
tactness and its compliance with the rules in force
at least once a year.
Fig. 17
Dispensing compartment
1-
Aspiration grid
2-
Feet cover
3-
Содержание Samba Top
Страница 1: ...InstallaTIon OPERATION MaIntenANCE EN English Doc No H3335EN00 Edition 1 12 2008 Samba Top...
Страница 2: ......
Страница 5: ......
Страница 6: ......
Страница 68: ...Sx49600...
Страница 69: ...Samba Plus Top SCHEMA ELETTRICO WIRING DIAGRAM...
Страница 70: ...Sx49700...
Страница 71: ...Samba Plus Top Schema elettrico porta Door wiring diagram...
Страница 72: ...Custom version Sx49802...
Страница 73: ...Samba Plus Top Schema elettrico cassetti Trays wiring diagram...
Страница 76: ......