12
© by NECTA VENDING SOLUTIONS SpA
01-2003 197 00
CHECKING AND ADJUSTING
THE MACHINE SETTINGS
To get the best results from the product used, the following
should be checked:
For coffee
That the used coffee dose is lightly compressed and
damp.
The grade of grinding of ground coffee.
The dose weight of ground coffee.
The dispensing temperature.
The water dose.
For instant products
The dose weight of the instant products.
The drink temperature.
The water dose.
Should the standard settings need to be changed, pro-
ceed as indicated in the next sections of this manual.
The weight of instant products, the water dose and tem-
perature are directly controlled by the microprocessor.
To adjust them it is therefore necessary to follow the
programming procedures.
Fig. 11
1 - Brewing chamber
2 - External disk
3 - Upper piston
4 - Lower piston
5 - Pre-brewing spring
6 - Swinging lever
STANDARD SETTINGS
The vending machine is supplied with the following set-
tings:
- coffee temperature (at the spout) approx. 70÷80°C;
- instant product temperature (at the spout) approx.
70÷80°C;
The machine standard settings assign the same price,
expressed in number of basic coins, to all selections.
ADJUSTING THE BREWING
CHAMBER VOLUME SETTING
When the upper piston is correctly positioned, the coffee
unit can operate with coffee doses of 5.5 to 8.5 g.
To change the piston position (see Fig. 12) do as follows:
- remove the snap ring from its seat;
- place the piston in the proper adjusting notches:
.less deep notches for 5.5 to 7.5 g doses;
.deeper notches for 6.5 to 8.5 g doses.
Fig. 12
1 - Snap ring
2 - Upper piston
3 - Reference fins
Содержание Colibri
Страница 2: ......
Страница 4: ......
Страница 40: ...Sx35401...
Страница 41: ...Colibr Espresso...
Страница 42: ...Sx35600 Sx35600...
Страница 43: ...Colibr Colibr Instant Instant...
Страница 44: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 45: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 46: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 48: ......