![NEC UNIVERGE NEAX 2000 IPS Скачать руководство пользователя страница 438](http://html1.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_system-manual_3962828438.webp)
CHAPTER 5 OPERATION TEST
– 424 –
NWA-008853-001 Rev.3.0
97ch5001.fm
Alarm Indications on 30DTI
LED
LED INDICATION
FAULT
NORMAL
FAULT
CAUSE
ACTION
MRMT
Off
On
Multi Frame Align-
ment signals can-
not be sent to the
remote PBX
Confirm the switch setting on the
DTI card indicating an alarm.
Replace the DTI card not indicat-
ing an alarm, with a spare.
AIS
Off
On
Remote PBX is in
the local loopback
state
Check the switch settings of the remote
DTI card.