CHAPTER 3 SYSTEM DATA PROGRAMMING
– 218 –
NWA-008853-001 Rev.3.0
97ch3003.fm
Example of the programming (PN-AP00-B with AP00 program)
Example 1:
Data Assignment of SMDR output for Center Office
In a Centralized Billing Office, the following four patterns of SMDR output can be selected.
(1) To SMDR 0 (Port 0): Sending of billing information from both a Center Office and Local Offices.
(2) To SMDR 1 (Port 0): Sending of billing information from both a Center Office and Local Offices.
(3) To SMDR 0 (Port 0): Sending of billing information from Local Offices.
To SMDR 1 (Port 1): Sending of billing information of a Center Office.
(4) To SMDR 0 (Port 0): Sending of billing information of a Center Office.
To SMDR 1 (Port 1): Sending of billing information from Local Offices.
• Data assignment of each pattern for Center Office
PATTERN
TO
FROM
CMD001>
80/100/
120/140
CMD
001>239
CMD016
XX16,
XX21,
XX30
XX17,
XX22,
XX55
1
SMDR 0
Center Office C
and Local Office
A/B
4
1
1
0
2
SMDR 1
Center Office C
and Local Office
A/B
5
2
0
1
3
SMDR 0 Local Office A/B
4
1
SMDR 1 Center Office C
5
0
1
4
SMDR 0 Center Office C
4
1
0
SMDR 1 Local Office A/B
5
2
Local Office
OFFICE
A
Center Office
OFFICE
C
Local Office
OFFICE
B
SMDR 0
SMDR 1
CENTRALIZED BILLING-CCIS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...