– 369 –
NWA-008853-001 Rev.3.0
97ch4001.fm
Lamp Indications
Switch Settings
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally.
LC
Green
Remains lit when communications are normally ongoing with the com-
mon signaling channel data links connected.
LPB
Green
Remains lit when a loopback test is in progress.
CRC
Red
Remains lit when detecting Cyclic Redundancy Checking (CRC)
errors.
PCM
Red
Remains lit when detecting PCM signal loss.
FRM
Red
Remains lit when detecting Frame Alignment signal loss.
RMT
Red
Remains lit when receiving Frame Alignment signal loss alarm from a
distant office.
AIS
Red
Remains lit when a pattern of consecutive “1” is received.
The distant office transmits this signal for a loopback test.
BL
Red
B channel status
ON
: More than 10 channels are busy
OFF
: All channels are idle
Flash (60 IPM) : Only one channel is busy
Flash (120 IPM): 2 through 10 channels are busy
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
0-3
Not used
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05.
Continued on next page
F
4
AP No.
SW1-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
PN-24CCTA (CCT)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...