CHAPTER 3 SYSTEM DATA PROGRAMMING
– 214 –
NWA-008853-001 Rev.3.0
97ch3003.fm
DESCRIPTION
DATA
Assign the data as follows.
• For Local Office:
1st Data
2nd Data
CCIS channel No.
0
(0-7) for
Center Office
• For Tandem Office:
1st Data
2nd Data
CCIS channel No.
0
(0-7) for
Center Office
CCIS channel No.
1
(0-7) for
Local Office
See
Example 3: Data Assignment of CMA7
Y=03, 04
.
Page 227
•
(1)
(2)
Y=03
0-7: CCIS channel No.
0 : Distant end is Center Office
1 : Distant end is Local Office
Assign Centralized Billing destination.
•
(1)
(2)
Y=04
0-7: CCIS channel No.
00001-16367: Point Code of Center Office.
See
Example 3: Data Assignment of CMA7
Y=03, 04
.
Page 227
Specify the station number sent to the 2400
IPX through CCIS for SMDR.
NOTE:
If the Center Office is the 2400 IPX,
CM65 Y=26 is required.
•
(1)
(2)
Y=26
Tenant No. of Stations
0 : My Line No.
1 : Sub Line No.
Assign the Charging Station Class number to
each station number.
•
(1)
(2)
Y=45
X-XXXXXXXX: Station No.
00-15 : Station Class No.
A
CMA7
CM65
CM12
B
CENTRALIZED BILLING-CCIS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...