CHAPTER 3 SYSTEM DATA PROGRAMMING
– 278 –
NWA-008853-001 Rev.3.0
97ch3004.fm
HOT LINE-CCIS
General Description
This feature allows two stations, at different nodes in the CCIS network, to be mutually associated on an
automatic ring down basis through the CCIS network.
Programming
Use the Hot Line-Outside feature.
DESCRIPTION
DATA
Assign a Hot Line to the required stations.
•
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
04: Hot Line
Allocate memory area Hot Line-Outside calls.
For example, to assign 10 Hot Line-Outside
calls into No. 100 through No. 109 Memory
Slots, 2nd data is “100010”. Abbreviated
Codes are automatically assigned as shown be-
low:
(1)
(2)
65: For Hot Line-Outside
XXX ZZZ
XXX: 000-299 (Stating Memory Slot No.
in blocks)
ZZZ : 001-300 (No. of Memory Slots to be
assigned in blocks)
Assign the destination party’s number to each
Memory Slot number.
•
(1)
(2)
Y=0
000-299: Memory Slot No.
XXXX
YY...Y
XXXX : Access Code (Maximum 4 digits)
: Separator Mark
YY...Y : Calling Party’s No.
(Maximum 26 digits)
Define the Hot Line pairs.
•
(1)
(2)
Y=00-99 Hot Line Pair No.
0: Calling Side
1: Called Outside Side
C XX (for Called Party)
XX: 00-09 (Abbreviated Code given by
CM71)
START
CM12
CM71
Memory Slot 100
Memory Slot 109
~
Abbrev. Codes
00
09
~
CM72
,
,
CM52
A
HOT LINE-CCIS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...