– 394 –
NWA-008853-001 Rev.3.0
97ch4001.fm
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
Set SW0-1 and SW0-2 as follows:
NOTE 4:
When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards mounted
in PIM0 to “OFF”.
NOTE 5:
Mount the DTI card which receives a source clock signal into PIM0.
NOTE 6:
This card must be reset after the SW0-3 to SW0-7 switch settings. Set the MB switch to UP and
then DOWN.
CONDITIONS
DTI0
DTI1
DTI2
· · · · ·
DTI7
REMARKS
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
When one DTI is
provided.
ON OFF
–
–
–
–
–
–
MP card will receive the
clock signal from DTI0 at
its PLO0 input.
When more than
one DTI is pro-
vided.
ON OFF OFF ON OFF OFF
OFF OFF
MP card will receive the
clock signal from DTI0 at
its PLO0 input, under nor-
mal conditions.
Should a clock failure occur
with DTI0, MP card will
automatically switch to the
PLO1 input which gets
clock from DTI1.
JULY/01/2006
PN-24DTA-C (DTI)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...