![NEC UNIVERGE NEAX 2000 IPS Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_system-manual_3962828158.webp)
CHAPTER 3 SYSTEM DATA PROGRAMMING
– 144 –
NWA-008853-001 Rev.3.0
97ch3002.fm
• For BLF message receiving office (Office B, C)
DESCRIPTION
DATA
Provide Busy Lamp Field (BLF)-CCIS to each
CCH number.
•
(1)
(2)
Y=30
0-7: CCH No.
0: To provide
To the virtual LEN, assign the station number
of the other office which is accommodated to
the BLF, as follows.
For closed numbering system: station number
For open numbering system: Access code + of-
fice station number
(1)
(2)
000-255: Virtual LEN
X-XXXXXXXX: Station No.
NOTE:
Amount of Access Code + Office
No. + Station No. must be no
more than 8 digits.
Specify whether the station number assigned
by CM11 is own office station or the other of-
fice station
•
(1)
(2)
Y=40
X-XXXXXXXX: Station No. assigned by
CM11
0 : Other office station
1 : Own office station
Assign the station number of the other office to
the keys on the DSS Console.
(1)
(2)
DSS Console No. (00-31) +
+ DSS Key
No. (00-59)
X-XXXXXXXX: Station No. assigned by
CM11
Assign the station number of the other office to
the One Touch keys on the D
term
.
•
(1)
(2)
Y=0
X YY Z
X : 0-9: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
X-XXXXXXXX: Station No. assigned by
CM11
Specify whether the line lockout indication is
available on the DSS Console.
(1)
(2)
274
0 : Available
1 : Not available
START
CMA7
CM11
CM13
CM97
,
CM74
CM08
END
BUSY LAMP FIELD (BLF)-CCIS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...