![NEC UNIVERGE NEAX 2000 IPS Скачать руководство пользователя страница 309](http://html1.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_system-manual_3962828309.webp)
CHAPTER 3 SYSTEM DATA PROGRAMMING
– 295 –
NWA-008853-001 Rev.3.0
97ch3004.fm
MULTIPLE CONSOLE OPERATION-CCIS
General Description
This feature provides console operation where Attendant Consoles are installed in more than one node in
the CCIS network.
Station Application
Attendant Console
Programming
DESCRIPTION
DATA
Assign the card number of interface circuit for
the ATTCON/DESKCON to its associated
LEN.
NOTE:
We recommend the setting of
ATTCON number by CM14, when
using Series 3200 R6.2 software or
later.
(1)
(2)
000-763: LEN
E000-E007: ATTCON No.
Assign the card number of interface circuit for
the ATTCON/DESKCON to its associated
LEN.
[Series 3200 R6.2 software required]
(1)
(2)
XX ZZZ (LEN)
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
E000-E007: ATTCON No.
NONE : No data
Set the terminating system for the incoming
calls to ATTCON/DESKCON.
•
•
•
•
(1)
(2)
Y=02 Day Mode
Y=03 Night Mode
Y=40 Mode A
Y=41 Mode B
000-254: Trunk No.
14: Attendant Console
Assign the required Attendant Call Selection
keys, and Function keys to each ATTCON/
DESKCON.
If no data is set, the default setting is as next
page.
•
(1)
(2)
Y=00
ATTCON No. (E000-E007) +
+ Key
No.
F6000-F6067: Type of Calls to be assigned
F6100-F6245: Functions to be assigned
START
CM10
CM14
CM30
CM90
,
A
MULTIPLE CONSOLE OPERATION-CCIS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Страница 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...