CHAPTER 3 SYSTEM DATA PROGRAMMING
– 257 –
NWA-008853-001 Rev.3.0
97ch3004.fm
DATA LINE SECURITY-CCIS
General Description
This feature allows the lines which are used for data transmission through CCIS to be protected from
interruptions such as Attendant Camp-On, Busy Verification-CCIS, Executive Right of Way, and Atten-
dant Override.
Programming
Operating Procedure
No manual operation is required.
DESCRIPTION
DATA
Assign the function of Analogue Data station
(Single Line Station with FAX or MODEM.)
to required stations.
•
(1)
(2)
Y=07
X-XXXXXXXX: Station No.
0: Data station
START
CM13
END