When time difference from the UTC is set:
When the time is indicated by UTC (Universal Time Coordinated), set the time difference from the UTC
by using the "tstimezone" command. When the time is indicated by Localtime, go to step 4.
Type “tstimezone --old h” or “tstimezone --old h, m” command to change time zone.
Value “h” is the number of hour difference from the UTC. Valid values are -12 through 12.
Value “m” is the number of minute difference from the hour offset “h”. This value is an option and
valid values are -30, 0, or 30.
If the time difference from the UTC is "-3.5" hours.
ALE044120T2:admin> tstimezone –old -3, -30
System Time Zone change will take effect at next reboot.
ALE044120T2:admin>
IMPORTANT:
The time of the clock built in the 8G FC Switch is based on the UTC. Setting the
difference of the time from the UTC allows the local time to be displayed instead.
The time display setting of the 8G FC Switch is set to “JST” time display when the 8G
FC Switch is shipped from the factory. When you use the 8G FC Switch as time
difference setting from the UTC time, change the time area to the “UTC” time before
setting time difference from the UTC.
4.
Set the time of the built-in clock by using the "date" command.
<Example of time setting>
ALE044120T2:admin> date 0928154209
Mon Sep 28 15:42:00 Localtime 2009
ALE044120T2:admin>
Command parameters:
date mmddHHMMyy
Parameters:
mm = Month (01 – 12)
dd = Date (01 – 31)
HH = Hour (00 – 23)
MM = Minute (00 – 59)
yy = Lower two digits of dominical year (00 - 99)
- 153 -
Содержание SigmaBlade N8406-040(F)
Страница 2: ... 2 ...
Страница 121: ... AG モード接続例 ブレード収納ユニット4台とiStorage WB3x0A NF9340 SS017 SS018 SS019 2台をAGモードで接続する場合 121 ...
Страница 205: ... 205 ...