CHAPTER 2 INSTALLATION
BACKUP CPU SYSTEM
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0
Page 225
Installation Procedure
Install the Backup CPU system according to the procedure below.
•
When Not Using Key FD (See below)
•
When Using Key FD (See next page)
For switch settings on the MP card (PN-CP20), see
For mounting locations of the MP card, see “
Mounting Locations of MP Cards
”.
•
When Not Using Key FD
(1)
Set the SW3 switch on the MP0 card to 2/3 (Off-line), and mount the MP0 card into MP00
slot.
(2)
Turn the system power ON.
(3)
Connect the MAT to the MP0 card, and clear all system data by CM00.
(4)
Assign the necessary office data to the MP0 card.
Date and time must be assigned by CM02.
(5)
For automatic office data copy, assign the following data.
Automatic office data copy:
Copy the office data once in a day at the predetermined time.
CM43Y=4>00: HH MM
HH: 00-23 (Hour)
MM: 00-59 (Minute)
NONE
: 0200 (2:00 AM)
(6)
Set the SW3 switch on the MP1 card to B.
(7)
Flip the MB switch on the MP1 card to ON (UP position), and mount the MP1 card into MP01
slot.
(8)
Flip the MB switch on the MP1 card to OFF (DOWN position).
- A few seconds later, the MN lamp on the PWR card lights in yellow. Now the system data
is cleared.
(9)
Flip the MB switch on the MP0 and MP1 cards to ON (UP position), and set the SW3 on the
MP0 and MP1 cards to 0 (On-line).
(10) Flip the MB switch on the MP0 card to OFF (DOWN position), and confirm if the RUN lamp
on the MP0 card lights.
(11) Flip the MB switch on the MP1 card to OFF (DOWN position).
- The MP0 acts. The RUN lamp on the MP0 card flashes at 120IPM.
- The MP1 card comes into a stand by mode. The STBY lamp lights and the RUN lamp
flashes at a slow pace, on the MP1 card.
- 3 to 6 minutes later, the office data copy from the MP0 to the MP1 card starts. The RUN
lamp on the MP1 card flashes intermittently.
- When the office data copy finishes (maximum 20 minutes later), the RUN lamp on the
MP1 card flashes in a slow pace.
▲
Содержание NEAX2000 IVS2
Страница 1: ...FEBRUARY 2001 NECAmerica Inc ND 70928 E ISSUE 3 STOCK 151998 Installation Procedure Manual...
Страница 19: ...NEAX2000 IVS2 Installation Procedure Manual Page x ND 70928 E Issue 3 0 This page is for your notes...
Страница 73: ...This page is for your notes NEAX2000 IVS2 Installation Procedure Manual Page 44 ND 70928 E Issue 3 0...
Страница 259: ...NEAX2000 IVS2 Installation Procedure Manual Page 230 ND 70928 E Issue 3 0 This page is for your notes...