CHAPTER 2 INSTALLATION
Built-in SMDR (MP)
NEAX2000 IVS
2
Installation Procedure Manual
Page 208
ND-70928 (E), Issue 3.0
Built-in SMDR (MP)
The MP card provides a S-10 interface port for SMDR/MCI.
No.0/No. 1 Port : Async.: 1200/2400/4800/9600/19200 bps
•
Direct connection
Connect the SMDR terminal and/or the VMS to the RS 0-RS 1port of the PN-CP14/
PN-CP20 card using the RS RVS-15 (S) CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as
shown below.
Figure 2-102 SMDR/MCI Terminal Direct Connection
•
Connection via MODEM
When the cable length between the PBX and the terminal is more than 15 m (49.2 ft.),
connect the SMDR terminal to the RS0 Port of the PN-CP14 card through the MODEMs
using the RS NORM-4 (S) CA-A as shown below.
Figure 2-103 SMDR Terminal Connection via MODEMs
PN-CP14
RS 0
RS RVS-15 (S) CA-A: 15 m (49.2 ft.)
PBX
15 m (49.2 ft.) MAX.
TO S-10
PORT
SMDR0/SMDR1/
RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C: 4 m (13.1 ft.)
PN-CP20
MCI (VMS)
RS 1
PN-CP14
RS 1
PBX
MODEM
MODEM
2P
RS NORM-4 CA-A/
RS NORM-4S CA-A: 4 m (13.1 ft.)
MORE THAN 15 m (49.2 ft.)
MODEM INTERFACE
CABLE (STRAIGHT)
TO S-10
PORT
SMDR0/SMDR1/
PN-CP20
RS 0
MCI (VMS)
Содержание NEAX2000 IVS2
Страница 1: ...FEBRUARY 2001 NECAmerica Inc ND 70928 E ISSUE 3 STOCK 151998 Installation Procedure Manual...
Страница 19: ...NEAX2000 IVS2 Installation Procedure Manual Page x ND 70928 E Issue 3 0 This page is for your notes...
Страница 73: ...This page is for your notes NEAX2000 IVS2 Installation Procedure Manual Page 44 ND 70928 E Issue 3 0...
Страница 259: ...NEAX2000 IVS2 Installation Procedure Manual Page 230 ND 70928 E Issue 3 0 This page is for your notes...