CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIB (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0
Page 317
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
NOTE 2: Time Slots 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control signal.
NOTE 3: This setting must be identical with the opposite DAIA card.
SW3 (DIP SW)
1
Set the equalizer according to the
cable length between the system
and the CSU.
OFF
2
OFF
3
OFF
4
Always set to OFF
JPS (Jumper pin)
UP
Neutral grounding on the
transmitting line is provided.
Neutral grounding on the
transmitting line is not provided.
JPR (Jumper pin)
UP
Neutral grounding on the receiving
line is provided.
Neutral grounding on the receiving
line is not provided.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
SW
-1
SW
-2
SW
-3
CABLE
LENGTH
ON
ON
ON
0 - 40 m
(0-131.2 ft.)
ON
ON
OFF
40 - 80 m
(131.2-262.5 ft.)
ON
OFF
ON
80 - 120 m
(262.5-394 ft.)
ON
OFF
OFF
120 - 160 m
(394-525 ft.)
OFF
ON
ON
160 - 200 m
(525-656 ft.)
OFF OFF
OFF
Signal is not sent
ON
ON
OFF
DOWN
DOWN
Содержание NEAX2000 IVS2
Страница 1: ...FEBRUARY 2001 NECAmerica Inc ND 70928 E ISSUE 3 STOCK 151998 Installation Procedure Manual...
Страница 19: ...NEAX2000 IVS2 Installation Procedure Manual Page x ND 70928 E Issue 3 0 This page is for your notes...
Страница 73: ...This page is for your notes NEAX2000 IVS2 Installation Procedure Manual Page 44 ND 70928 E Issue 3 0...
Страница 259: ...NEAX2000 IVS2 Installation Procedure Manual Page 230 ND 70928 E Issue 3 0 This page is for your notes...