CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIA (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
Page 256
ND-70928 (E), Issue 1.0
NOTE 3: When clock source office signal is supplied via the line between the main site and the
remote site, set the SW1-1 and SW1-2 as the following table. In this case, DAIA cards
(DAIA0, DAIA1) must be mounted in PIM0.
NOTE 4: The time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control sig-
nal.
NOTE 5: This setting must be identical with the opposite DAIB card.
CONDITIONS
DAIA0
DAIA1
DAIA2
REMARKS
SW
1-1
SW
1-2
SW
1-1
SW
1-2
SW
1-1
SW
1-2
One DAIA card
is provided.
ON
OFF
–
–
–
–
The clock signal is
sent to PLO0 of MP
card via supply route
0 (DAIA0).
Two or three
DAIA cards are
provided.
ON
OFF
OFF
ON
OFF
OFF
The clock signal sup-
ply route is automati-
cally changed to the
route 1 (DAIA1), if a
transmission line fail-
ure occurs on the
supply route 0.