CHAPTER 2 INSTALLATION
Built-in SMDR (MP)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 191
Built-in SMDR (MP)
The MP card provides a RS-232C interface port for SMDR connection.
No.0 Port : Async.: 1200/2400/4800/9600/19200 bps
•
Direct connection
Connect the SMDR terminal to the RS 0 Port of the PN-CP14 card using the RS RVS-15 (S)
CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below.
Figure 2-96 SMDR Terminal Direct Connection
•
Connection via MODEM
When the cable length between the PBX and the terminal is more than 15 m (49.2 ft.), con-
nect the SMDR terminal to the RS0 Port of the PN-CP14 card through the MODEMs using
the RS NORM-4 (S) CA-A as shown below.
Figure 2-97 SMDR Terminal Connection via MODEMs
PN-CP14
RS 0
RS RVS-15 (S) CA-A: 15 m (49.2 ft.)
PBX
15 m (49.2 ft.) MAX.
TO RS-232C
PORT
SMDR
RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C: 4 m (13.1 ft.)
PN-CP14
RS 0
PBX
MODEM
MODEM
2P
RS NORM-4 CA-A/
RS NORM-4S CA-A: 4 m (13.1 ft.)
MORE THAN 15 m (49.2 ft.)
MODEM INTERFACE
CABLE (STRAIGHT)
TO RS-232C
PORT
SMDR