CHAPTER 1 GENERAL INFORMATION
Equipment Name and Function
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 13
EQUIPMENT NAME AND FUNCTION
This section explains the names and functions of the equipment (modules, installation hardware,
circuit cards) used in the system.
Module/Installation Hardware
This table shows the names and functions of the modules.
Table 1-1 Module Name and Function
EQUIPMENT
NAME
FUNCTIONAL
NAME
FUNCTION
SN1480
PIMAF
PIM
Port Interface Module (PIM)
Max. 64 physical ports per PIM.
Houses two batteries for protection from short power
interruption (for 30 minutes).
At maximum configuration, the system consists of eight PIMs
and provides a total of 512 physical ports (64 ports x 8).
SN1545
BASERE
BASE/TOP
ASSEM
Base/Top Cover Assembly
One base and top cover assembly is required for each stack.
TOP COVER
ASSEM
SN1526
BATTMF
BATTM
Battery Module for housing PIM or CS (ZT) backup batteries
Houses two pairs of batteries for protection from long power
interruption (for 3 hours).