CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 195
•
Connection via MODEM
When the cable length between the PBX and the terminal is more than 15 m (49.2 ft), MO-
DEMs are required. Use RS RORM-4(S) CA-A as shown below. See also
Figure 2-99
.
Figure 2-101 SMDR/PMS/MCI Terminal Connection via MODEMs
RS0 - RS3
PN-
PBX
(PIM0 - PIM7)
RS NORM-4S CA-A:
4m (13.1 ft.)
MODEM
MODEM
2P
MORE THAN 15m (49.2 ft.)
MODEM: FULL DUPLEX (4W)
1200 bps (LEASED TYPE)
INTERFACE CABLE
(FOR STRAIGHT
CONNECTION)
TO RS-232C PORT
RS NORM-4 CA-A/
SMDR0/SMDR1/
PMS/MCI (VMS)
AP00-B