CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS
2
Installation Procedure Manual
Page 64
ND-70928 (E), Issue 1.0
• Connection of PIM and BASE for Fixed/Stationary Equipment
(1) Mount the PIM on the BASE by placing it over the hooks.
(2) Slide the PIM into the inner end.
(3) Fix the PIM to the BASE with three screws.
NOTE:
Screws are attached to the Module.
Figure 2-13 Connection of PIM and BASE
SCREWS
BASE
PIM
BASE
HOOKS
SLIDE PIM INTO
INNER END.