background image

 

                            SKY-8101D

 

 

 

                                  Compact 1U High Performance Server 

 

 

   

 

 

 

 

 

Summary of Contents for SKY-8101D

Page 1: ...SKY 8101D Compact 1U High Performance Server ...

Page 2: ...4 Connecting to Monitor Keyboard and Mouse 17 2 3 5 Connecting to the Serial Console 17 2 3 6 Installing an OS 20 3 Components Installation Removal 24 3 1 Removing the Top Cover 24 3 2 Installing the Top Cover 24 3 3 Removing the PSU 24 3 4 Installing the PSU 24 3 5 Removing the HDD tray 25 3 6 Installing the HDD 25 3 7 Removing the FAN module 25 3 8 Installing the FAN module 25 3 9 Removing the D...

Page 3: ...gedness reliability and long system lifecycles required by the industry With integrated security and compression offload based on Intel QuickAssist technology and two 10GbE ports with SR IOV and RDMA support the system offers best in class integration in a compact form factor The SKY 8101D accommodates up to four 10 5 PCIe x16 Gen3 adapters designed for applications requiring high TDP high speed n...

Page 4: ...system 1536GB Socket 24x 288 pin DIMM PCIe Expansion slot Total 4x FH L PCIe x16 Gen3 slots Optional 1x PCIe x8 for OCP Ethernet card up to dual port 25G Note In the optional sku 2x NVMe interfaces will be configured into 1x PCIe x8 for OCP NIC IO Front IO 1x PWR button 1x ID button 2x USB3 0 2 0 1x RJ45 console 5x LEDs Power ID 3x SW definable 1x VGA port 2x 10GbE SFP Rear IO 2x GbE LAN RJ45 2x h...

Page 5: ...s Thermal Control Three separate thermal zones for motherboard and PCIe cards Reliability Resilient to single fan failure System Management Advantech BMC Aspeed AST2500 BMC Advanced Lights Out Management compliant to IPMI2 0 with security and availability enhancements iKVM Support Configurable shared or dedicated NIC support Physical Dimension W x D x H 438 00 x 749 7 x 44 20 mm 17 24 x 29 50 x 1 ...

Page 6: ...1 3 2 System Dimensions The system dimensions in mm are shown below Unit mm inch Figure 2 2 System Dimension ...

Page 7: ...0 ports ADA Front I O 1x VGA port AEA Front I O Option 1 10GbE PHY OCP Mezzanine card SFI from PCH LED behavior Status LED Right 10GbE Green 10 100 1000Mbps Off Actively LED Left Link Active Green Option 2 25GbE LAN OCP Ethernet card PCIex8 Note In Option 2 2x NVMe interfaces will be configured into 1x PCIe x8 so the platform can only support up to 2x NVMe SSD 2x SATA SAS HDD SSD 1 4 1 1 Disk Bay ...

Page 8: ...ll as drive LEDs Figure 5 5 Disk Tray Table 1 4 Disk Tray Item Element Description ADT1A LOCK Locks the tray in the bay when in the left position ADT2A LED Activity LED amber ADT3A LED Status LED ADT4A Button Pushing the button will allow the tray handle to open if unlocked ADT5A Handle Tray handle 1 4 1 2 LEDs Details The SKY 8101D supports an array of status LEDs and buttons at location B ...

Page 9: ...cal discrete sensors is asserted e g processor thermal trip PSU failure AB3A MJR Red Major Alarm System Status LED One system status LED in red color is provided for the SKY 8101D system chassis The system status LED behavior is based on Platform Event Filtering PEF alert rules which can be configured by user The default configuration is to light up if any critical sensor threshold or critical dis...

Page 10: ...MI command Without the rearm procedure the event cannot be cleared even when the chassis is closed The SKY 8101D intrusion sensor id is 0x08 Please use the following IPMI raw command to clear rearm intrusion alarm ipmitool raw 0x04 0x2a 0x08 0x80 0x01 0x00 0x01 0x00 1 4 1 4 Front Button Details The SKY 8101D supports two buttons at the front Figure 7 7 Front Buttons Table 1 6 Front Buttons Item El...

Page 11: ...n AAA PSU Module Hot swappable redundant 1200W AC or 800W AC PSU ABA PCIe Slots Four FH L PCIe x16 Gen3 slots ACA Copper port Two copper GbE management ports LED behavior Actively LED Right Link Active Green Status LED Left 1000Mbps Green 10 100Mbps Amber Note MGMT1 BMC IP can be set under BIOS ...

Page 12: ...actory authorized service personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment Do not install substitute parts or perform any unauthorized modification of the equipment or the warranty may be voided Contact your local Advantech representative for service and repair to make sure that all safety featur...

Page 13: ...ive foam and the accessory box embedded to the foam Remove the accessory box first and then pull out the unit including the protective foam using both hands Now remove the foam and the plastic sleeve on the unit After unpacking the unit please check for any visible damage of the unit and contact your Advantech representative in case of any issue Please note that unless agreed otherwise power cords...

Page 14: ...the rack is adequate for the unit weight and the application Use the mounting hardware recommended by the rack manufacturer to mount the unit in the rack For mounting screws compatible with the rack design must be used and hand tightened to ensure secure installation Choose a mounting location that does not block any air inlet and air outlet areas of the unit it is also recommended to factor in he...

Page 15: ...on To install the chassis slide rail on the SKY 8101D chassis please follow below instruction Step 1 Remove the chassis inner member Step 2 Mount the chassis inner member to the chassis Step 3 Attach the cabinet outer member to the rail ...

Page 16: ...Step 4 Mount the chassis into the cabinet ...

Page 17: ...rts a VGA Port and two USB ports at the front of the unit for connection of a monitor keyboard and mouse Please refer to Section 1 4 1 for information on the location of the related connectors 2 3 5 Connecting to the Serial Console The SKY 8101D supports the operation via a serial terminal connection by default for scenarios where a directly attached monitor keyboard and mouse are not available or...

Page 18: ...r serial line and 115200 for speed no parity no flow control 2 Check Serial for connection type 3 Check VT100 for keypad in the keyboard submenu 4 Check Colour or Both for Indicate bolded text in the colours submenu 5 Click the Open button and a PuTTY terminal screen will appear Figure 2 2 PuTTY Session Configuration Figure 2 3 PuTTY Serial Configuration ...

Page 19: ...Figure 2 4 PuTTY Keyboard Settings Figure 2 5 PuTTY Colour Settings If the connection is successful you should be able to see the BIOS Power On POST screen after powering the unit ...

Page 20: ...have a reference OS installed by default The unit will be ready to boot the reference OS from the mass storage option selected 2 3 6 2 Installing and or boot and OS from a USB key To boot from a USB stick 1 Create a Live USB stick using LiLi available via http www linuxliveusb com or a similar tool If you want to use a serial console please make sure to configure the Linux properly 115200bd 8N1 no...

Page 21: ...the documentation of the related network installer and or Linux distribution Please make sure you configure the network installer image properly for the Ethernet port device of the SKY 8101D that you plan to use for the installation 2 3 6 4 Booting an OS via network boot The SKY 8101D supports booting over network via PXE To boot an OS via network please make sure the following BIOS options In the...

Page 22: ...and go to the BIOS by hitting the DEL key Once you are in the bios track to the POST BOOT tab then inside the CSM Parameters there select the Network option to Legacy After doing this do not for get to change the boot sequence Figure 2 7 Booting the Client with Legacy Option Screen_1 Figure 2 8 Booting the Client with Legacy Option Screen_2 Booting the client with UEFI option Power up the client s...

Page 23: ... UEFI Option Screen_1 After doing this do not for get to change the boot sequence Reboot the client system and to get the installation menu And hit enter to begin the installation Figure 2 10 Booting the Client with UEFI Option Screen_2 ...

Page 24: ...ngaged with the chassis b Make sure the guide pin and the guide pin hole are well aligned c Grab the latch handle and slide the top cover forwards d Lock the latch with a screw driver 3 3 Removing the PSU a Grab the PSU handle and unlock the module by pulling the PSU lock to the left b Hold the lock and extract the PSU module 3 4 Installing the PSU a Insert PSU module into the bay b The lock will ...

Page 25: ...y handle c Lock the tray by moving the lock to the right 3 7 Removing the FAN module a Unlock the latch with a screw driver b Grab the handle and slide the rear top cover backwards c Slide the middle top cover backwards and lift off d Extract the fan module 3 8 Installing the FAN module a Install the fan module b Slide the middle top cover forwards c Grab the latch handle and slide the rear top co...

Page 26: ...f Pull the DIMM module out vertically 3 10 Installing the DIMM module a Insert the DIMM using the guide rails on the left and right of the socket b Install the air duct and tighten the thumb screws c Grab the latch handle and slide the top cover forwards d Lock the latch with a screw driver 3 11 Removing the CPU a Unlock the latch with a screw driver b Grab the handle and slide the rear top cover ...

Page 27: ... Caution Please remove the cage with small and gentle motions Quick and abrupt extract motions may break the gold fingers of the riser card 3 14 Installing the PCIe card a Insert the card to be installed b Install and fasten the fixing screw c Insert the PCIe cage to be installed d Connect the cable to the main board and fasten the 3 thumb screws e Slide the middle top cover forward f Grab the lat...

Page 28: ...ng 0x07 AP initialization after microcode loading 0x08 North Bridge initialization after microcode loading 0x09 South Bridge initialization after microcode loading 0x0A Unused 0x0B Cache initialization 0x0E Microcode not found 0x0F Microcode not loaded 0x10 PEI Core is started 0x11 Pre memory CPU initialization is started 0x12 Pre memory CPU initialization CPU module specific 0x13 Pre memory CPU i...

Page 29: ...0x18 Pre Memory North Bridge initialization North Bridge module specific ...

Page 30: ...y 0x2F Memory initialization other 0x30 Reserved for ASL 0x31 Memory Installed 0x32 CPU post memory initialization is started 0x33 CPU post memory initialization Cache initialization 0x34 CPU post memory initialization Application Processor s AP initialization 0x35 CPU post memory initialization Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initi...

Page 31: ...ze or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecified memory initialization error 0x55 Memory not installed 0x56 Invalid CPU type or Speed 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU micro code is not found or micro code update is failed 0x5A Internal CPU error 0x5B Reset PPI is not available 0x60 DXE Core...

Page 32: ...ion is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x72 South Bridge DXE Initialization South Bridge module specific 0x73 South Bridge DXE Initialization South Bridge module specific 0x74 South Bridge DXE Initialization South Bridge module specific 0x75 South Bridge DXE Initialization South Bridge module specific 0x76 South Bridge DXE Initia...

Page 33: ...x9C USB Detect 0x9D USB Enable 0xA0 IDE initialization is started 0xA1 IDE Reset 0xA2 IDE Detect 0xA3 IDE Enable 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL 0xAB Setup Input Wait 0xAC Reserved for ASL 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Ru...

Page 34: ...he Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found 0xD7 No Console Input Devices are found 0xD8 Invalid password 0xD9 Error loading Boot Option LoadImage returned error 0xDA Boot Option is failed StartImage returned error 0xDB Flash update is failed 0xDC Reset protocol is not ...

Page 35: ...POST Code Description 0xE9 S3 Resume PPI not Found 0xEA S3 Resume Boot Script Error 0xEB S3 OS Wake Error 0xF0 0xF4 Unused 0xf8 0xFA Unused ...

Page 36: ...placement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered for example Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe...

Page 37: ...terface LOM Lights Out Management MAC Media Access Control MTBF Mean Time Between Failures NIC Network Interface Controller NMC Network Mezzanine Card NVRAM Non volatile Random Access Memory OOS Out Of Service PCH Platform Controllers Hub PCIe PCI Express PECI Platform Environment Control Interface PCI SIG PCI Special Interest Group PICMG PCI Industrial Computer Manufacturers Group POST Power On S...

Page 38: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permission of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2021 ...

Reviews: