10-4 Troubleshooting
STATUS LED
indication
Description
Action
On (green)
The server is operating
normally.
–
The server is operating with
the memory in degraded
state.
Identify the device in degraded state by using
the BIOS setup utility "SETUP," and replace it as
soon as possible.
Blinking (green)
The server is operating with
the CPU error being
detected.
Check the failed CPU status by using the BIOS
setup utility "SETUP," and replace it as soon as
possible.
Off
The server is off-powered.
Power on the server.
POST is in progress.
Wait for a while. The STATUS LED turns green
when POST is completed.
A CPU error occurred.
A CPU thermal error was
detected.
A watchdog timer has timed
out.
An uncorrectable memory
error was detected.
A PCI system error occurred.
A PCI parity error occurred.
A PCI bus error occurred.
Cycle power to the server. If POST displays an
error message, take a note on the message and
contact your service representative.
Memory dumping is
requested.
Wait until memory dumping completes.
A thermal error was detected.
Check internal fans for dust or debris. Also
make sure that the fans are firmly connected.
If this error indication persists, contact your
service representative.
On (amber)
A voltage error was detected.
Contact your service representative.
A fan alarm was detected.
Make sure that the fan units are firmly
connected.
If this error indication persists, contact your
service representative.
A thermal warning was
detected.
Check internal fans for dust or debris. Also
make sure that the fan units are firmly
connected.
If this error indication persists, contact your
service representative.
Blinking (amber)
A voltage warning was
detected
Contact your service representative.
An error was detected on
either of the hard disk drives.
Replace the hard disk drive.
Содержание N8100-1575F
Страница 16: ...x This page is intentionally left blank...
Страница 19: ...Notes on Using Your Server 1 3 2 5 inch Hard Disk Drive Model Attached to the bottom of the chassis...
Страница 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Страница 67: ...Setting Up Your Server 3 13 4 To remove the rail assembly pull out the rail toward you while pushing the lever...
Страница 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Страница 256: ...8 12 Installing and Using Utilities This page is intentionally left blank...
Страница 268: ...9 12 Maintenance This page is intentionally left blank...
Страница 372: ...C 2 IRQ This page is intentionally left blank...
Страница 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 378: ...E 4 Product Configuration Record Table This page is intentionally left blank...