Configuring Your Server 4-41
Default settings and their explanation
Item
Default
Description
Change
Battery Backup
Present
None
Displays Properties.
•
When battery is installed: Present
•
When battery is not installed: None
–
Set Factory Defaults
[No]
Yes
Restores vendor's factory defaults.
Prohibited *1
Cluster Mode
Disabled
–
Prohibited
Rebuild Rate
30
Recommended value: 30
Permitted
Patrol Read Rate
30
Recommended value: 30
Permitted
BGI Rate
30
Recommended value: 30
Permitted
CC Rate
30
Recommended value: 30
Permitted
Reconstruction Rate
30
Recommended value: 30
Permitted
Adapter BIOS
[Enabled]
Disabled
–
Prohibited
Coercion Mode
[None]
128MB-way
1GB-way
–
Prohibited
PDF Interval
300
–
Prohibited
Alarm Control
[Disabled]
Enabled
Silence
Disabled: Does not issue an alarm.
Prohibited *2
Cache Flush Interval 4
–
Prohibited
Spinup Drive Count
2
–
Prohibited
Spinup Delay
12
–
Prohibited
StopOnError
[Disabled]
Enabled
–
Prohibited
Stop CC On Error
[No]
Yes
Specify the operation at error detection in
Consistency Check.
No: Recover and resume.
Yes: Abort
Permitted
Maintain PD Fail
History
[Disabled]
Enabled
–
Prohibited
Schedule CC
Supported
Set the scheduled consistency check.
Permitted
*1 Do not perform "Set Factory Defaults". If performed, the NEC's factory-set value will no longer
be restored.
How to change setting value
On [Adapter Properties] screen, change a parameter to desired value, and then click [Submit] at the
center of the screen to determine the new value.
When you determine the parameter value, click [Back] or [Home] to go back to the Main Menu.
Содержание N8100-1417F
Страница 16: ...x This page is intentionally left blank...
Страница 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Страница 108: ...4 40 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information...
Страница 119: ...Configuring Your Server 4 51 Use this menu to define several physical drives PD as a disk group DG...
Страница 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Страница 195: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 220: ...7 12 Maintenance This page is intentionally left blank...
Страница 300: ...9 42 Upgrading Your Server Removal Remove the HDD cage in the reverse procedure of the installation...
Страница 316: ...9 58 Upgrading Your Server Removal Remove the 5 25 inch device in the reverse procedure of the installation...
Страница 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Страница 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Страница 362: ...A 2 Specifications This page is intentionally left blank...
Страница 370: ...C 2 IRQ This page is intentionally left blank...
Страница 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...