Upgrading Your Server 9-43
2.5-inch HDD Cage
Installing an optional HDD cage in the 2.5-inch hard disk drive bay on the front of the server allows
the server to be equipped with up to eight hard disk drives in addition to eight drives normally
installable. Hard disk drives are not installed in the HDD cage. Purchase them additionally.
IMPORTANT:
Use the hard disk drives authorized by NEC. Installing a third-party
hard disk drive may cause a failure of the server as well as the hard
disk drive. Purchase hard disk drives of the following models:
– N8150-199 (36.3GB, 15000 rpm, SAS)
– N8150-200 (73.2GB, 15000 rpm, SAS)
– N8150-201 (146.5GB, 15000 rpm, SAS)
– N8150-226 (300GB, 15000 rpm, SAS)
To use RAID 5, RAID 6, or RAID 10 with Internal RAID Controller
(equivalent to N8103-116), you need to additionally install the
optional N8103-119 RAID Upgrade Kit.
A hard disk drive having thickness of about 0.6 inch can be inserted to each of the eight slots in the
HDD cage. PORT8 to PORT15 are assigned in the order from right to left of additional 2.5-inch
HDD cage.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Additional 2.5-inch
HDD cage
PORT8 to PORT15
from right to left
PORT0 to PORT7
from right to left
Содержание N8100-1417F
Страница 16: ...x This page is intentionally left blank...
Страница 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Страница 108: ...4 40 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information...
Страница 119: ...Configuring Your Server 4 51 Use this menu to define several physical drives PD as a disk group DG...
Страница 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Страница 195: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 220: ...7 12 Maintenance This page is intentionally left blank...
Страница 300: ...9 42 Upgrading Your Server Removal Remove the HDD cage in the reverse procedure of the installation...
Страница 316: ...9 58 Upgrading Your Server Removal Remove the 5 25 inch device in the reverse procedure of the installation...
Страница 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Страница 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Страница 362: ...A 2 Specifications This page is intentionally left blank...
Страница 370: ...C 2 IRQ This page is intentionally left blank...
Страница 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...