4-28 Configuring Your Server
RAID10
Data to be recorded is distributed to two HDDs in mirroring mode. Then, each mirrored data is
written onto HDD by striping. Owing to this feature, high disk access performance of RAID0 and,
in addition, high reliability of RAID1 can be achieved.
RAID Controller
HDD 1
HDD 2
Stripe 1
HDD 3
Stripe 3
Stripe 1
Stripe 3
Stripe 2
Stripe 4
Stripe 5
Stripe 5
Stripe 6
HDD 4
Stripe 2
Stripe 4
Stripe 6
RAID1
RAID1
RAID0
RAID50
Data is distributed to HDDs by striping with distributed parity, and then written onto HDDs by
striping. Owing to this feature, high disk access performance of RAID0 and, in addition, high
reliability of RAID5 can be achieved.
RAID Controller
HDD 1
HDD 2
Stripe 1
HDD 3
Stripe 6
Stripe 2
Parity (5, 6)
Parity (1, 2)
Stripe 5
Parity (9, 10)
Stripe 9
Stripe 10
HDD 4
Stripe 3
Stripe 8
Parity (11, 12)
HDD 5
HDD 6
Stripe 4
Parity (7, 8)
Stripe 11
Parity (3, 4)
Stripe 7
Stripe 12
RAID5
RAID5
RAID0
Содержание N8100-1417F
Страница 16: ...x This page is intentionally left blank...
Страница 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Страница 108: ...4 40 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information...
Страница 119: ...Configuring Your Server 4 51 Use this menu to define several physical drives PD as a disk group DG...
Страница 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Страница 195: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 220: ...7 12 Maintenance This page is intentionally left blank...
Страница 300: ...9 42 Upgrading Your Server Removal Remove the HDD cage in the reverse procedure of the installation...
Страница 316: ...9 58 Upgrading Your Server Removal Remove the 5 25 inch device in the reverse procedure of the installation...
Страница 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Страница 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Страница 362: ...A 2 Specifications This page is intentionally left blank...
Страница 370: ...C 2 IRQ This page is intentionally left blank...
Страница 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...